Hae
Aineistot 1-5 / 5
The detection of solid phosphorus and fluorine in the dust from the coma of comet 67P/Churyumov-Gerasimenko
<p>Here, we report the detection of phosphorus and fluorine in solid
particles collected from the inner coma of comet
67P/Churyumov-Gerasimenko measured with the COmetary Secondary Ion Mass
Analyser (COSIMA) instrument ...
The oxygen isotopic composition (18O/16O) in the dust of comet 67P/Churyumov-Gerasimenko measured by COSIMA on-board Rosetta
<p>The oxygen isotopic ratio <sup>18</sup>O/<sup>16</sup>O has been
measured in cometary gas for a wide variety of comets, but the only
measurements in cometary dust were performed by the Stardust cometary
sample ...
Optical properties of cometary particles collected by the COSIMA mass spectrometer on-board Rosetta during the rendezvous phase around comet 67P/Churyumov–Gerasimenko
<p>40 000 collected cometary particles have been identified on the 21 targets exposed by the COSIMA experiment on-board Rosetta
to the environment of comet 67P/Churyumov–Gerasimenko from 2014 August
to 2016 September. The images of the targets where obtained by the
COSIMA microscope (Cosiscope, 13.95 μm pixel<sup>−1</sup>) with near
grazing incidence, which is optimal for the primary objective (detection
of collected particles) but very challenging for photometry. However,
more than 300 of the collected particles are larger than 100 μm which
makes it possible to derive constraints on the optical properties from
the distribution of light levels within the particles. Two types of
particles collected by COSIMA (compact particles and cluster particles)
have been identified in Langevin et al. The best estimate reflectance
factors of compact particles range from 10 per cent to 23 per cent. For
cluster particles (>90 per cent of large collected particles), the
comparison of the signal profiles with illumination from two opposite
directions shows that there is scattering within the particles, with a
mean free path in the 20–25 μm range, which requires high porosity. The
best estimate reflectance factors of cluster particles range from
3 per cent to 22 per cent. This range of reflectance factors overlaps
with that obtained from observations of the cometary nucleus at
macroscopic scales by OSIRIS and it is consistent with that measured for
interplanetary dust particles collected in the stratosphere of the
Earth.</p>...
Similarities in element content between comet 67P/Churyumov–Gerasimenko coma dust and selected meteorite samples
<p>We have analysed the element composition and the context of particles
collected within the coma of 67P/Churyumov–Gerasimenko with Rosetta’s
COmetary Secondary Ion Mass Analyzer (COSIMA). A comparison has been
made ...