Hyppää sisältöön
    • Suomeksi
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

Robust PPG Peak Detection Using Dilated Convolutional Neural Networks

Laitala Juho; Azimi Iman; Rahmani Amir M.; Kazemi Kianoosh; Liljeberg Pasi

Robust PPG Peak Detection Using Dilated Convolutional Neural Networks

Laitala Juho
Azimi Iman
Rahmani Amir M.
Kazemi Kianoosh
Liljeberg Pasi
Katso/Avaa
sensors-22-06054-v2.pdf (5.724Mb)
Lataukset: 

MDPI
doi:10.3390/s22166054
URI
https://www.mdpi.com/1424-8220/22/16/6054
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2022091258585
Tiivistelmä

Accurate peak determination from noise-corrupted photoplethysmogram (PPG) signal is the basis for further analysis of physiological quantities such as heart rate. Conventional methods are designed for noise-free PPG signals and are insufficient for PPG signals with low signal-to-noise ratio (SNR). This paper focuses on enhancing PPG noise-resiliency and proposes a robust peak detection algorithm for PPG signals distorted due to noise and motion artifact. Our algorithm is based on convolutional neural networks (CNNs) with dilated convolutions. We train and evaluate the proposed method using a dataset collected via smartwatches under free-living conditions in a home-based health monitoring application. A data generator is also developed to produce noisy PPG data used for model training and evaluation. The method performance is compared against other state-of-the-art methods and is tested with SNRs ranging from 0 to 45 dB. Our method outperforms the existing adaptive threshold, transform-based, and machine learning methods. The proposed method shows overall precision, recall, and F1-score of 82%, 80%, and 81% in all the SNR ranges. In contrast, the best results obtained by the existing methods are 78%, 80%, and 79%. The proposed method proves to be accurate for detecting PPG peaks even in the presence of noise.

Kokoelmat
  • Rinnakkaistallenteet [19207]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste