Molecular design of radiocopper-labelled Affibody molecules

Grimm S; Gronroos TJ; Haaparanta-Solin M; Anderson CJ; Garousi J; Karlstrom AE; Ferdani R; Yim CB; Yue Y; Rajander J; Perols A; Tolmachev V; Orlova A; Solin O

Molecular design of radiocopper-labelled Affibody molecules

Grimm S
Gronroos TJ
Haaparanta-Solin M
Anderson CJ
Garousi J
Karlstrom AE
Ferdani R
Yim CB
Yue Y
Rajander J
Perols A
Tolmachev V
Orlova A
Solin O
Katso/Avaa
Publisher's version (1.448Mb)
Lataukset: 

NATURE PUBLISHING GROUP
doi:10.1038/s41598-018-24785-2
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2021042719225
Tiivistelmä
The use of long-lived positron emitters Cu-64 or Cu-61 for labelling of Affibody molecules may improve breast cancer patients' stratification for HER-targeted therapy. Previous animal studies have shown that the use of triaza chelators for Cu-64 labelling of synthetic Affibody molecules is suboptimal. In this study, we tested a hypothesis that the use of cross-bridged chelator, CB-TE2A, in combination with Gly-Glu-Glu-Glu spacer for labelling of Affibody molecules with radiocopper would improve imaging contrast. CB-TE2A was coupled to the N-terminus of synthetic Affibody molecules extended either with a glycine (designation CB-TE2A-G-ZHER2:342) or Gly-Glu-Glu-Glu spacer (CB-TE2A-GEEE-ZHER2:342). Biodistribution and targeting properties of Cu-64-CB-TE2A-G-ZHER2:342 and Cu-64-CB-TE2A-GEEE-ZHER2:342 were compared in tumor-bearing mice with the properties of Cu-64-NODAGA-ZHER2:S1, which had the best targeting properties in the previous study. Cu-64-CB-TE2A-GEEE-ZHER2:342 provided appreciably lower uptake in normal tissues and higher tumor-to-organ ratios than Cu-64-CB-TE2A-GZHER2:342 and Cu-64-NODAGA-ZHER2:S1. The most pronounced was a several-fold difference in the hepatic uptake. At the optimal time point, 6 h after injection, the tumor uptake of Cu-64-CB-TE2A-GEEE-ZHER2: 342 was 16 +/- 6% ID/g and tumor-to-blood ratio was 181 +/- 52. In conclusion, a combination of the cross-bridged CB-TE2A chelator and Gly-Glu-Glu-Glu spacer is preferable for radiocopper labelling of Affibody molecules and, possibly, other scaffold proteins having high renal re-absorption.
Kokoelmat
  • Rinnakkaistallenteet [19207]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste