Hyppää sisältöön
    • Suomeksi
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

Vacuum ultraviolet photon-mediated production of [F-18]F-2

Kirjavainen AK; Keller T; Krzyczmonik A; Forsback S; Solin O

Vacuum ultraviolet photon-mediated production of [F-18]F-2

Kirjavainen AK
Keller T
Krzyczmonik A
Forsback S
Solin O
Katso/Avaa
Publisher´s PDF (662.4Kb)
Lataukset: 

WILEY
doi:10.1002/jlcr.3489
URI
http://onlinelibrary.wiley.com/doi/10.1002/jlcr.3489/epdf
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2021042716855
Tiivistelmä
The chemistry of F-2 and its derivatives are amenable to facile aliphatic or aromatic substitution, as well as electrophilic addition. The main limitation in the use of [F-18]F-2 for radiopharmaceutical synthesis is the low specific activity achieved by the traditional methods of production. The highest specific activities, 55GBq/mol, for [F-18]F-2 have been achieved so far by using electrical discharge in the post-target production of [F-18]F-2 gas from [F-18]CH3F. We demonstrate that [F-18]F-2 is produced by illuminating a gas mixture of neon/F-2/[F-18]CH3F with vacuum ultraviolet photons generated by an excimer laser. We tested several illumination chambers and production conditions. The effects of the initial amount of [F-18]F-, amount of carrier F-2, and number of 193-nm laser pulses at constant power were evaluated regarding radiochemical yield and specific activity. The specific activity attained for [F-18]F-2-derived [F-18]NFSi was 10.3 +/- 0.9GBq/mol, and the average radiochemical yield over a wide range of conditions was 6.7% from [F-18]F-. The production can be improved by optimization of the synthesis device and procedures. The use of a commercially available excimer laser and the simplicity of the process can make this method relatively easy for adaptation in radiochemistry laboratories.
Kokoelmat
  • Rinnakkaistallenteet [19207]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste