RoboPol: a four-channel optical imaging polarimeter

T. Hovatta; D. Modi; I. Papamastorakis; C. V. Rajarshi; T. J. Pearson; A. N. Ramaprakash; E. Pazderski; P. Reig; E. Angelakis; A. Słowikowska; G. Panopoulou; H. K. Das; A. Kougentakis; D. Blinov; S. Kiehlmann; G. Paterakis; L. Fuhrmann; I. Myserlis; C. Casadio; S. Maharana; A. Mahabal; A. Kus; O. G. King; V. Pavlidou; N. Kylafis; E. Paleologou; K. Tassis; I. Papadakis; A. C. S. Readhead; P. Khodade; J. A. Zensus; A. Marecki; I. Liodakis

RoboPol: a four-channel optical imaging polarimeter

T. Hovatta
D. Modi
I. Papamastorakis
C. V. Rajarshi
T. J. Pearson
A. N. Ramaprakash
E. Pazderski
P. Reig
E. Angelakis
A. Słowikowska
G. Panopoulou
H. K. Das
A. Kougentakis
D. Blinov
S. Kiehlmann
G. Paterakis
L. Fuhrmann
I. Myserlis
C. Casadio
S. Maharana
A. Mahabal
A. Kus
O. G. King
V. Pavlidou
N. Kylafis
E. Paleologou
K. Tassis
I. Papadakis
A. C. S. Readhead
P. Khodade
J. A. Zensus
A. Marecki
I. Liodakis
Katso/Avaa
Publisher's PDF (3.327Mb)
Lataukset: 

OXFORD UNIV PRESS
doi:10.1093/mnras/stz557
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2021042822263
Tiivistelmä
We present the design and performance of RoboPol, a four-channel optical polarimeter operating at the Skinakas Observatory in Crete, Greece. RoboPol is capable of measuring both relative linear Stokes parameters q and u (and the total intensity I) in one sky exposure. Though primarily used to measure the polarization of point sources in the R band, the instrument features additional filters (B, V, and I), enabling multiwavelength imaging polarimetry over a large field of view (13.6' x 13.6'). We demonstrate the accuracy and stability of the instrument throughout its 5 yr of operation. Best performance is achieved within the central region of the field of view and in the R band. For such measurements the systematic uncertainty is below 0.1 per cent in fractional linear polarization, p (0.05 per cent maximum likelihood). Throughout all observing seasons the instrumental polarization varies within 0.1 per cent in p and within similar to 1 degrees in polarization angle.
Kokoelmat
  • Rinnakkaistallenteet [19207]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste