EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging

Roberto Sciagrà; Mark Lubberink; Fabien Hyafil; Antti Saraste; Riemer H. J. A. Slart; Denis Agostini; Carmela Nappi; Panagiotis Georgoulias; Jan Bucerius; Christoph Rischpler; Hein J. Verberne

EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging

Roberto Sciagrà
Mark Lubberink
Fabien Hyafil
Antti Saraste
Riemer H. J. A. Slart
Denis Agostini
Carmela Nappi
Panagiotis Georgoulias
Jan Bucerius
Christoph Rischpler
Hein J. Verberne
Katso/Avaa
Publishers's PDF (1.235Mb)
Lataukset: 

Springer Science and Business Media Deutschland GmbH
doi:10.1007/s00259-020-05046-9
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2021042822289
Tiivistelmä

The use of cardiac PET, and in particular of quantitative myocardial perfusion PET, has been growing during the last years, because scanners are becoming widely available and because several studies have convincingly demonstrated the advantages of this imaging approach. Therefore, there is a need of determining the procedural modalities for performing high-quality studies and obtaining from this demanding technique the most in terms of both measurement reliability and clinical data. Although the field is rapidly evolving, with progresses in hardware and software, and the near perspective of new tracers, the EANM Cardiovascular Committee found it reasonable and useful to expose in an updated text the state of the art of quantitative myocardial perfusion PET, in order to establish an effective use of this modality and to help implementing it on a wider basis. Together with the many steps necessary for the correct execution of quantitative measurements, the importance of a multiparametric approach and of a comprehensive and clinically useful report have been stressed.

Kokoelmat
  • Rinnakkaistallenteet [29335]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste