A Deep Learning-Based Automated CT Segmentation of Prostate Cancer Anatomy for Radiation Therapy Planning-A Retrospective Multicenter Study

Mokka M; Riener M; Heikkilä J; Pang EPP; Zolotuhhin D; Kiljunen T; Tuan JKL; Keyriläinen J; Adamson M; Nikkinen J; Heikkilä VP; Lehtiö K; Niemelä J; Kononen J; Löyttyniemi E; Kolk K; Gershkevitsh E; Borkvel A; Chua MLK; Seppälä J; Vuolukka K; Master Z; Joensuu T; Myllykangas M; Akram S; Kääriäinen OS

A Deep Learning-Based Automated CT Segmentation of Prostate Cancer Anatomy for Radiation Therapy Planning-A Retrospective Multicenter Study

Mokka M
Riener M
Heikkilä J
Pang EPP
Zolotuhhin D
Kiljunen T
Tuan JKL
Keyriläinen J
Adamson M
Nikkinen J
Heikkilä VP
Lehtiö K
Niemelä J
Kononen J
Löyttyniemi E
Kolk K
Gershkevitsh E
Borkvel A
Chua MLK
Seppälä J
Vuolukka K
Master Z
Joensuu T
Myllykangas M
Akram S
Kääriäinen OS
Katso/Avaa
Publisher's PDF (1.340Mb)
Lataukset: 

MDPI
doi:10.3390/diagnostics10110959
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2021042827384
Tiivistelmä
A commercial deep learning (DL)-based automated segmentation tool (AST) for computed tomography (CT) is evaluated for accuracy and efficiency gain within prostate cancer patients. Thirty patients from six clinics were reviewed with manual- (MC), automated- (AC) and automated and edited (AEC) contouring methods. In the AEC group, created contours (prostate, seminal vesicles, bladder, rectum, femoral heads and penile bulb) were edited, whereas the MC group included empty datasets for MC. In one clinic, lymph node CTV delineations were evaluated for interobserver variability. Compared to MC, the mean time saved using the AST was 12 min for the whole data set (46%) and 12 min for the lymph node CTV (60%), respectively. The delineation consistency between MC and AEC groups according to the Dice similarity coefficient (DSC) improved from 0.78 to 0.94 for the whole data set and from 0.76 to 0.91 for the lymph nodes. The mean DSCs between MC and AC for all six clinics were 0.82 for prostate, 0.72 for seminal vesicles, 0.93 for bladder, 0.84 for rectum, 0.69 for femoral heads and 0.51 for penile bulb. This study proves that using a general DL-based AST for CT images saves time and improves consistency.
Kokoelmat
  • Rinnakkaistallenteet [19204]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste