Hyppää sisältöön
    • Suomeksi
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of Ga-68-DOTA-Siglec-9 and F-18-Fluorodeoxyribose-Siglec-9: Inflammation Imaging and Radiation Dosimetry

Virtanen H; Airaksinen AJ; Tolvanen T; Roivainen A; Helariutta K; Veres TZ; Jalkanen S; Stahle M; Li XG; Saraste A; Knuuti J; Siitonen R; Silvola JMU; Hellberg S; Liljenback H; Autio A; Kakela M

Comparison of Ga-68-DOTA-Siglec-9 and F-18-Fluorodeoxyribose-Siglec-9: Inflammation Imaging and Radiation Dosimetry

Virtanen H
Airaksinen AJ
Tolvanen T
Roivainen A
Helariutta K
Veres TZ
Jalkanen S
Stahle M
Li XG
Saraste A
Knuuti J
Siitonen R
Silvola JMU
Hellberg S
Liljenback H
Autio A
Kakela M
Katso/Avaa
Publisher's version (3.215Mb)
Lataukset: 

WILEY-HINDAWI
doi:10.1155/2017/7645070
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2021042718612
Tiivistelmä
Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a ligand of inflammation-inducible vascular adhesion protein-1 (VAP1). We compared Ga-68-DOTA-and F-18-fluorodeoxyribose-(FDR) labeled Siglec-9motif peptides for PET imaging of inflammation. Methods. Firstly, we examined Ga-68-DOTA-Siglec-9 and F-18-FDR-Siglec-9 in rats with skin/muscle inflammation. We then studied F-18-FDR-Siglec-9 for the detection of inflamed atherosclerotic plaques in mice and compared it with previous Ga-68-DOTA-Siglec-9 results. Lastly, we estimated human radiation dosimetry fromthe rat data. Results. In rats, Ga-68-DOTA-Siglec-9 (SUV, 0.88 +/- 0.087) and F-18-FDR-Siglec-9 (SUV, 0.77 +/- 0.22) showed comparable (P = 0.29) imaging of inflammation. In atherosclerotic mice, 18 FFDR- Siglec-9 detected inflamed plaques with a target-to-background ratio (1.6 1/8 0.078) similar to previously tested Ga-68-DOTASiglec- 9 (P = 0.35). Humaneffectivedose estimates for Ga-68-DOTA-Siglec-9 and (18) F-FDR-Siglec-9were 0.024 and 0.022 mSv/MBq, respectively. Conclusion. Both tracers are suitable for PET imaging of inflammation. The easier production and lower cost of (68)GaDOTA-Siglec-9 present advantages over F-18-FDR-Siglec-9, indicating it as a primary choice for clinical studies.
Kokoelmat
  • Rinnakkaistallenteet [19207]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste