Hyppää sisältöön
    • Suomeksi
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

External validation of a deep learning-based algorithm for detection of tall cells in papillary thyroid carcinoma: A multicenter study

Stenman Sebastian; Bétrisey Sylvain; Vainio Paula; Huvila Jutta; Lundin Mikael; Linder Nina; Schmitt Anja; Perren Aurel; Dettmer Matthias S.; Haglund Caj; Arola Johanna; Lundin Johan

External validation of a deep learning-based algorithm for detection of tall cells in papillary thyroid carcinoma: A multicenter study

Stenman Sebastian
Bétrisey Sylvain
Vainio Paula
Huvila Jutta
Lundin Mikael
Linder Nina
Schmitt Anja
Perren Aurel
Dettmer Matthias S.
Haglund Caj
Arola Johanna
Lundin Johan
Katso/Avaa
1-s2.0-S2153353924000051-main.pdf (4.079Mb)
Lataukset: 

Elsevier
doi:10.1016/j.jpi.2024.100366
URI
https://doi.org/10.1016/j.jpi.2024.100366
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2025082788921
Tiivistelmä
The tall cell variant (TCV) is an aggressive subtype of papillary thyroid carcinoma (PTC). The TCV is defined as a PTC comprising at least 30% epithelial cells that are three times as tall as they are wide. In practice, this definition is difficult to adhere to, resulting in high inter-observer variability. In this multicenter study, we validated a previously trained deep learning (DL)-based algorithm for detection of tall cells on 160 externally collected hematoxylin and eosin (HE)-stained PTC whole-slide images. In a test set of 360 manual annotations of regions of interest from 18 separate tissue sections in the external dataset, the DL-based algorithm detected TCs with a sensitivity of 90.6% and a specificity of 88.5%. The DL algorithm detected non-TC areas with a sensitivity of 81.6% and a specificity of 92.9%. In the validation datasets, 20% and 30% TC thresholds correlated with a significantly shorter relapse-free survival. In conclusion, the DL algorithm detected TCs in unseen, external scanned HE tissue slides with high sensitivity and specificity without any retraining.
Kokoelmat
  • Rinnakkaistallenteet [29335]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste