Non-Invasive Hemodynamic Monitoring System Integrating Spectrometry, Photoplethysmography, and Arterial Pressure Measurement Capabilities

Sirkiä, Jukka-Pekka; Panula, Tuukka; Kaisti, Matti

Non-Invasive Hemodynamic Monitoring System Integrating Spectrometry, Photoplethysmography, and Arterial Pressure Measurement Capabilities

Sirkiä, Jukka-Pekka
Panula, Tuukka
Kaisti, Matti
Katso/Avaa
Advanced Science - 2024 - Sirkiä - Non‐Invasive Hemodynamic Monitoring System Integrating Spectrometry .pdf (3.101Mb)
Lataukset: 

Wiley-VCH
doi:10.1002/advs.202310022
URI
https://onlinelibrary.wiley.com/doi/10.1002/advs.202310022
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2025082789912
Tiivistelmä
Minimally invasive and non-invasive hemodynamic monitoring technologies have recently gained more attention, driven by technological advances and the inherent risk of complications in invasive techniques. In this article, an experimental non-invasive system is presented that effectively combines the capabilities of spectrometry, photoplethysmography (PPG), and arterial pressure measurement. Both time- and wavelength-resolved optical signals from the fingertip are measured under external pressure, which gradually increased above the level of systolic blood pressure. The optical channels measured at 434-731 nm divided into three groups separated by a group of channels with wavelengths approximately between 590 and 630 nm. This group of channels, labeled transition band, is characterized by abrupt changes resulting from a decrease in the absorption coefficient of whole blood. External pressure levels of maximum pulsation showed that shorter wavelengths (<590 nm) probe superficial low-pressure blood vessels, whereas longer wavelengths (>630 nm) probe high-pressure arteries. The results on perfusion indices and DC component level changes showed clear differences between the optical channels, further highlighting the importance of wavelength selection in optical hemodynamic monitoring systems. Altogether, the results demonstrated that the integrated system presented has the potential to extract new hemodynamic information simultaneously from macrocirculation to microcirculation.
Kokoelmat
  • Rinnakkaistallenteet [29335]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste