Hyppää sisältöön
    • Suomeksi
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

Multichannel Bed Based Ballistocardiography Heart Rate Estimation Using Continuous Wavelet Transforms and Autocorrelation

Elnaggar Ismail; Hurnanen Tero; Sandelin Jonas; Lahdenoja Olli; Airola Antti; Kaisti Matti; Koivisto Tero

Multichannel Bed Based Ballistocardiography Heart Rate Estimation Using Continuous Wavelet Transforms and Autocorrelation

Elnaggar Ismail
Hurnanen Tero
Sandelin Jonas
Lahdenoja Olli
Airola Antti
Kaisti Matti
Koivisto Tero
Katso/Avaa
Multichannel Bed Based Ballistocardiography Heart Rate Estimation Using Continuous Wavelet Transforms and Autocorrelation.pdf (724.0Kb)
Lataukset: 

doi:10.22489/CinC.2022.364
URI
https://cinc.org/archives/2022/pdf/CinC2022-364.pdf
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe202301265921
Tiivistelmä

Bed based ballistocardiography (BCG) is a prime candidate for at home and nighttime monitoring especially in the growing elderly population because co-operation from the user is not required to be able to record signals. One issue with BCG is that the signal quality has intraand inter-person variability based on factors such as age, gender, body position, and motion artifacts, making it challenging to accurately measure heart rate.

A rule-based algorithm which considers all eight available BCG channels simultaneously from a given time epoch was developed using continuous wavelet transform (CWT) to extract the localized time-frequency representation of each epoch and then an averaging method was applied across the different scales of the CWT to produce a 1-dimensional array. Autocorrelation was then applied to this array to produce a heart rate estimate based on the lag between the autocorrelation maximum and the first side peak. This method does not require identification of individual heart beats to estimate heart rate and does not require annotated training data.

This model produces an average mean absolute error (MAE) of 1.09 bpm across 40 subjects when compared to heart rate derived from ECG. This method produces competitive results without the need for annotated training data, which can be challenging to collect.

Kokoelmat
  • Rinnakkaistallenteet [29335]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste