Hyppää sisältöön
    • Suomeksi
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
  •   Etusivu
  • 3. UTUCris-artikkelit
  • Rinnakkaistallenteet
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

Concordant inter-laboratory derived concentrations of ceramides in human plasma reference materials via authentic standards

Torta F.; Hoffmann N.; Burla B.; Alecu I.; Arita M.; Bamba T.; Bennett S.A.L.; Bertrand-Michel J.; Brügger B.; Cala M.P.; Camacho-Muñoz D.; Checa A.; Chen M.; Chocholoušková M.; Cinel M.; Chu-Van E.; Colsch B.; Coman C.; Connell L.; Sousa B.C.; Dickens A.M.; Fedorova M.; Eiríksson F.F.; Gallart-Ayala H.; Ghorasaini M.; Giera M.; Guan X.L.; Haid M.; Hankemeier T.; Harms A.; Höring M.; Holčapek M.; Hornemann T.; Hu C.; Hülsmeier A.J.; Huynh K.; Jones C.M.; Ivanisevic J.; Izumi Y.; Köfeler H.C.; Lam S.M.; Lange M.; Lee J.C.; Liebisch G.; Lippa K.; Lopez-Clavijo A.F.; Manzi M.; Martinefski M.R.; Math R.G.H.; Mayor S.; Meikle P.J.; Monge M.E.; Moon M.H.; Muralidharan S.; Nicolaou A.; Nguyen-Tran T.; O'Donnell V.B.; Orešič M.; Ramanathan A.; Riols F.; Saigusa D.; Schock T.B.; Schwartz-Zimmermann H.; Shui G.; Singh M.; Takahashi M.; Thorsteinsdóttir M.; Tomiyasu N.; Tournadre A.; Tsugawa H.; Tyrrell V.J.; van der Gugten G.; Wakelam M.O.; Wheelock C.E.; Wolrab D.; Xu G.; Xu T.; Bowden J.A.; Ekroos K.; Ahrends R.; Wen

Concordant inter-laboratory derived concentrations of ceramides in human plasma reference materials via authentic standards

Torta F.
Hoffmann N.
Burla B.
Alecu I.
Arita M.
Bamba T.
Bennett S.A.L.
Bertrand-Michel J.
Brügger B.
Cala M.P.
Camacho-Muñoz D.
Checa A.
Chen M.
Chocholoušková M.
Cinel M.
Chu-Van E.
Colsch B.
Coman C.
Connell L.
Sousa B.C.
Dickens A.M.
Fedorova M.
Eiríksson F.F.
Gallart-Ayala H.
Ghorasaini M.
Giera M.
Guan X.L.
Haid M.
Hankemeier T.
Harms A.
Höring M.
Holčapek M.
Hornemann T.
Hu C.
Hülsmeier A.J.
Huynh K.
Jones C.M.
Ivanisevic J.
Izumi Y.
Köfeler H.C.
Lam S.M.
Lange M.
Lee J.C.
Liebisch G.
Lippa K.
Lopez-Clavijo A.F.
Manzi M.
Martinefski M.R.
Math R.G.H.
Mayor S.
Meikle P.J.
Monge M.E.
Moon M.H.
Muralidharan S.
Nicolaou A.
Nguyen-Tran T.
O'Donnell V.B.
Orešič M.
Ramanathan A.
Riols F.
Saigusa D.
Schock T.B.
Schwartz-Zimmermann H.
Shui G.
Singh M.
Takahashi M.
Thorsteinsdóttir M.
Tomiyasu N.
Tournadre A.
Tsugawa H.
Tyrrell V.J.
van der Gugten G.
Wakelam M.O.
Wheelock C.E.
Wolrab D.
Xu G.
Xu T.
Bowden J.A.
Ekroos K.
Ahrends R.
Wen
Katso/Avaa
s41467-024-52087-x.pdf (10.96Mb)
Lataukset: 

Nature Portfolio
doi:10.1038/s41467-024-52087-x
URI
https://doi.org/10.1038/s41467-024-52087-x
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2025082787222
Tiivistelmä
In this community effort, we compare measurements between 34 laboratories from 19 countries, utilizing mixtures of labelled authentic synthetic standards, to quantify by mass spectrometry four clinically used ceramide species in the NIST (National Institute of Standards and Technology) human blood plasma Standard Reference Material (SRM) 1950, as well as a set of candidate plasma reference materials (RM 8231). Participants either utilized a provided validated method and/or their method of choice. Mean concentration values, and intra- and inter-laboratory coefficients of variation (CV) were calculated using single-point and multi-point calibrations, respectively. These results are the most precise (intra-laboratory CVs ≤ 4.2%) and concordant (inter-laboratory CVs < 14%) community-derived absolute concentration values reported to date for four clinically used ceramides in the commonly analyzed SRM 1950. We demonstrate that calibration using authentic labelled standards dramatically reduces data variability. Furthermore, we show how the use of shared RM can correct systematic quantitative biases and help in harmonizing lipidomics. Collectively, the results from the present study provide a significant knowledge base for translation of lipidomic technologies to future clinical applications that might require the determination of reference intervals (RIs) in various human populations or might need to estimate reference change values (RCV), when analytical variability is a key factor for recall during multiple testing of individuals.
Kokoelmat
  • Rinnakkaistallenteet [27094]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste