Analysis of Unbalanced Magnetic Pull of a Solid Rotor Induction Motor in a Waste Heat Recovery Generator

Jastrzebski Rafal P; Pilat Adam K

Analysis of Unbalanced Magnetic Pull of a Solid Rotor Induction Motor in a Waste Heat Recovery Generator

Jastrzebski Rafal P
Pilat Adam K
Katso/Avaa
Analysis_of_Unbalanced_Magnetic_.pdf (10.45Mb)
Lataukset: 

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
doi:10.1109/TEC.2022.3227551
URI
https://doi.org/10.1109/TEC.2022.3227551
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe2025082787695
Tiivistelmä
In active magnetic bearing control systems, the performance of the closed-loop control and the application can be impaired by external disturbances. This article analyzes the unbalanced magnetic pull forces produced by the eccentricity of a high-speed 1MW 3-phase solid rotor induction motor. The effect of unbalanced magnetic pull on a five-degree-of-freedom active magnetic bearing control and the resulting vibrations are studied. Finite-element-method-based modeling of the electrical machine unbalanced magnetic pull and activemagnetic bearing forces is carried out, and the results are used in the harmonic force analysis and modeling of an active magnetic bearing-rotor system. The overall engineering model comprising the rotor dynamics, unbalanced magnetic pull derived by the finite elementmethod, active magnetic bearing forces, and the controller is tested by time-stepping simulations. The simulations and experimental results are reviewed. The severity of the unbalanced magnetic pull and its effects on the robustness of the active magnetic bearing closed-loop system in a hermetic steam turbogenerator applied in marine waste heat recovery systems are evaluated.
Kokoelmat
  • Rinnakkaistallenteet [27094]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste