Assessing the impact of signal quality on heart rate detection from long-term clinical wrist PPG under varying cardiac rhythms

Zhao, Yangyang; Lahdenoja, Olli; Sandelin, Jonas; Seifizarei, Sepehr; Anzanpour, Arman; Lehto, Joonas; Nuotio, Joel; Jaakkola, Jussi; Relander, Arto; Vasankari, Tuija; Airaksinen, Juhani; Kiviniemi, Tuomas; Kaisti, Matti; Koivisto, Tero

Assessing the impact of signal quality on heart rate detection from long-term clinical wrist PPG under varying cardiac rhythms

Zhao, Yangyang
Lahdenoja, Olli
Sandelin, Jonas
Seifizarei, Sepehr
Anzanpour, Arman
Lehto, Joonas
Nuotio, Joel
Jaakkola, Jussi
Relander, Arto
Vasankari, Tuija
Airaksinen, Juhani
Kiviniemi, Tuomas
Kaisti, Matti
Koivisto, Tero
Katso/Avaa
1-s2.0-S1746809425011991-main.pdf (2.884Mb)
Lataukset: 

Elsevier
doi:10.1016/j.bspc.2025.108688
URI
https://doi.org/10.1016/j.bspc.2025.108688
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on:
https://urn.fi/URN:NBN:fi-fe202601215513
Tiivistelmä

Reliable heart rate (HR) detection is essential for long-term cardiac monitoring, particularly in hospitalized patients with complex conditions. Due to its optical and non-invasive nature, photoplethysmography (PPG) is inherently susceptible to motion artifacts and noise. These challenges intensify under arrhythmic conditions such as atrial fibrillation (AF), where signal distortions may blur the boundary between poor-quality segments and pathological rhythms, potentially impairing downstream tasks like HR estimation. This study developed a signal quality assessment (SQA) algorithm designed for this high-risk clinical population and evaluated its robustness through HR estimation. We collected 24-hour synchronous PPG and electrocardiogram (ECG) recordings from 49 hospitalized cardiac patients, with all PPG segments manually annotated for quality. External validation was conducted using the MIMIC-IV dataset. To avoid dependence on specific segment lengths or classifier types, we assessed SQA performance using seven machine learning models and four segmentation lengths. The SQA framework was then applied to HR estimation to evaluate clinical utility. We implemented a Standard Deviation of Successive Differences (SDSD)-based peak filtering method and compared it with an autocorrelation-based approach under different cardiac rhythm conditions. Threshold tuning in both SQA classification and SDSD filtering was conducted to explore the balance between data usability and reliable HR estimation. The proposed model achieved an AUROC of 96.1% (Sinus Rhythm (SR) + AF), with 90.6% on MIMIC-IV. Predicted SQA labels closely matched manual annotations, with mean absolute error (MAE) differences of 0.08 bpm (SR+AF), 0.25 bpm (SR), 0.62 bpm (AF), and 0.53 bpm (MIMIC-IV). SDSD reduced MAE by 46.57% for SR+AF, 41.67% for SR, and 49.69% for AF, further demonstrating the effectiveness of integrating SQA into HR estimation workflows.

Kokoelmat
  • Rinnakkaistallenteet [29335]

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetAsiasanatTiedekuntaLaitosOppiaineYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy

Turun yliopiston kirjasto | Turun yliopisto
julkaisut@utu.fi | Tietosuoja | Saavutettavuusseloste