Impact of Intraprocedural Pressure Changes on Hemodynamic Outcome During Self-Expanding TAVR
| dc.contributor.author | Pykäri Jouni | |
| dc.contributor.author | Vasankari Tuija | |
| dc.contributor.author | Ylitalo Antti | |
| dc.contributor.author | Porela Pekka | |
| dc.contributor.author | Paana Tuomas | |
| dc.contributor.author | Malmberg Markus | |
| dc.contributor.author | Laurila Sanna | |
| dc.contributor.author | Koskinen Juho | |
| dc.contributor.author | Koivisto Tero | |
| dc.contributor.author | Savontaus Mikko | |
| dc.contributor.organization | fi=kliininen laitos|en=Department of Clinical Medicine| | |
| dc.contributor.organization | fi=sisätautioppi|en=Internal Medicine| | |
| dc.contributor.organization | fi=terveysteknologia|en=Health Technology| | |
| dc.contributor.organization | fi=tyks, vsshp|en=tyks, varha| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.28696315432 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.40502528769 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.61334543354 | |
| dc.contributor.organization-code | 2610303 | |
| dc.converis.publication-id | 179240121 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/179240121 | |
| dc.date.accessioned | 2026-01-21T15:03:57Z | |
| dc.date.available | 2026-01-21T15:03:57Z | |
| dc.description.abstract | <p><b>Introduction:</b> During the transcatheter aortic valve replacement (TAVR) procedure, hemodynamic measurements can be used to evaluate transcatheter heart valve (THV) performance. We hypothesized that the occurrence of a significant decrease in invasive aortic pressure immediately after annular contact by a self-expanding THV indicates effective annular sealing. This phenomenon could thus be used as a marker for the occurrence of paravalvular leak (PVL).<br></p><p><b>Methods:</b> Thirty-eight patients undergoing TAVR procedure with a self-expandable Evolut R or Evolut Pro (Medtronic) valve prosthesis were included in the study. Drop in aortic pressure during valve expansion was defined as a decrease in systolic pressure of 30 mmHg immediately after annular contact. The primary endpoint was the occurrence of more than mild PVL immediately after valve implantation.<br></p><p><b>Results:</b> A pressure drop was seen in 60.5% (23/38) of patients. More than mild PVL requiring balloon post-dilatation (BPD) was significantly more frequent in patients who did not have a systolic pressure decrease > 30 mmHg during valve implantation (46.7% [7/15] vs. 13.0% [3/23], respectively; p = 0.03). Patients without a systolic pressure decrease > 30 mmHg also had a lower mean cover index on computed tomography analysis (16.2% vs. 13.3%; p = 0.016). The 30-day outcomes were similar between the two groups, and echocardiography at 30 days demonstrated more than none/trace PVL in 21.1% (8/38) of patients, with no difference between the two groups.<br></p><p><b>Conclusion:</b> A decrease in aortic pressure after annular contact is associated with an increased probability of good hemodynamic outcome after self-expanding TAVR implantation. In addition to other methods, this parameter could be used as an additional marker for optimal valve positioning and hemodynamic outcome during the implantation procedure.<br></p> | |
| dc.identifier.eissn | 2193-6544 | |
| dc.identifier.jour-issn | 2193-8261 | |
| dc.identifier.olddbid | 214056 | |
| dc.identifier.oldhandle | 10024/197074 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/56298 | |
| dc.identifier.url | https://link.springer.com/article/10.1007/s40119-023-00307-8 | |
| dc.identifier.urn | URN:NBN:fi-fe2023041937541 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Pykäri, Jouni | |
| dc.okm.affiliatedauthor | Vasankari, Tuija | |
| dc.okm.affiliatedauthor | Ylitalo, Antti | |
| dc.okm.affiliatedauthor | Porela, Pekka | |
| dc.okm.affiliatedauthor | Paana, Tuomas | |
| dc.okm.affiliatedauthor | Malmberg, Markus | |
| dc.okm.affiliatedauthor | Laurila, Sanna | |
| dc.okm.affiliatedauthor | Koskinen, Juho | |
| dc.okm.affiliatedauthor | Koivisto, Tero | |
| dc.okm.affiliatedauthor | Savontaus, Mikko | |
| dc.okm.affiliatedauthor | Dataimport, tyks, vsshp | |
| dc.okm.discipline | 3121 Internal medicine | en_GB |
| dc.okm.discipline | 3121 Sisätaudit | fi_FI |
| dc.okm.internationalcopublication | not an international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | SPRINGER LONDON LTD | |
| dc.publisher.country | United Kingdom | en_GB |
| dc.publisher.country | Britannia | fi_FI |
| dc.publisher.country-code | GB | |
| dc.relation.doi | 10.1007/s40119-023-00307-8 | |
| dc.relation.ispartofjournal | Cardiology and Therapy | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/197074 | |
| dc.title | Impact of Intraprocedural Pressure Changes on Hemodynamic Outcome During Self-Expanding TAVR | |
| dc.year.issued | 2023 |
Tiedostot
1 - 1 / 1