Impact of Intraprocedural Pressure Changes on Hemodynamic Outcome During Self-Expanding TAVR

dc.contributor.authorPykäri Jouni
dc.contributor.authorVasankari Tuija
dc.contributor.authorYlitalo Antti
dc.contributor.authorPorela Pekka
dc.contributor.authorPaana Tuomas
dc.contributor.authorMalmberg Markus
dc.contributor.authorLaurila Sanna
dc.contributor.authorKoskinen Juho
dc.contributor.authorKoivisto Tero
dc.contributor.authorSavontaus Mikko
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=terveysteknologia|en=Health Technology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.28696315432
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code2610303
dc.converis.publication-id179240121
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/179240121
dc.date.accessioned2026-01-21T15:03:57Z
dc.date.available2026-01-21T15:03:57Z
dc.description.abstract<p><b>Introduction:</b> During the transcatheter aortic valve replacement (TAVR) procedure, hemodynamic measurements can be used to evaluate transcatheter heart valve (THV) performance. We hypothesized that the occurrence of a significant decrease in invasive aortic pressure immediately after annular contact by a self-expanding THV indicates effective annular sealing. This phenomenon could thus be used as a marker for the occurrence of paravalvular leak (PVL).<br></p><p><b>Methods:</b> Thirty-eight patients undergoing TAVR procedure with a self-expandable Evolut R or Evolut Pro (Medtronic) valve prosthesis were included in the study. Drop in aortic pressure during valve expansion was defined as a decrease in systolic pressure of 30 mmHg immediately after annular contact. The primary endpoint was the occurrence of more than mild PVL immediately after valve implantation.<br></p><p><b>Results:</b> A pressure drop was seen in 60.5% (23/38) of patients. More than mild PVL requiring balloon post-dilatation (BPD) was significantly more frequent in patients who did not have a systolic pressure decrease > 30 mmHg during valve implantation (46.7% [7/15] vs. 13.0% [3/23], respectively; p = 0.03). Patients without a systolic pressure decrease > 30 mmHg also had a lower mean cover index on computed tomography analysis (16.2% vs. 13.3%; p = 0.016). The 30-day outcomes were similar between the two groups, and echocardiography at 30 days demonstrated more than none/trace PVL in 21.1% (8/38) of patients, with no difference between the two groups.<br></p><p><b>Conclusion:</b> A decrease in aortic pressure after annular contact is associated with an increased probability of good hemodynamic outcome after self-expanding TAVR implantation. In addition to other methods, this parameter could be used as an additional marker for optimal valve positioning and hemodynamic outcome during the implantation procedure.<br></p>
dc.identifier.eissn2193-6544
dc.identifier.jour-issn2193-8261
dc.identifier.olddbid214056
dc.identifier.oldhandle10024/197074
dc.identifier.urihttps://www.utupub.fi/handle/11111/56298
dc.identifier.urlhttps://link.springer.com/article/10.1007/s40119-023-00307-8
dc.identifier.urnURN:NBN:fi-fe2023041937541
dc.language.isoen
dc.okm.affiliatedauthorPykäri, Jouni
dc.okm.affiliatedauthorVasankari, Tuija
dc.okm.affiliatedauthorYlitalo, Antti
dc.okm.affiliatedauthorPorela, Pekka
dc.okm.affiliatedauthorPaana, Tuomas
dc.okm.affiliatedauthorMalmberg, Markus
dc.okm.affiliatedauthorLaurila, Sanna
dc.okm.affiliatedauthorKoskinen, Juho
dc.okm.affiliatedauthorKoivisto, Tero
dc.okm.affiliatedauthorSavontaus, Mikko
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSPRINGER LONDON LTD
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1007/s40119-023-00307-8
dc.relation.ispartofjournalCardiology and Therapy
dc.source.identifierhttps://www.utupub.fi/handle/10024/197074
dc.titleImpact of Intraprocedural Pressure Changes on Hemodynamic Outcome During Self-Expanding TAVR
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s40119-023-00307-8.pdf
Size:
592.12 KB
Format:
Adobe Portable Document Format