Air abrasion device versus sandblasting device for surface pretreatment of CAD-CAM prosthetic materials

dc.contributor.authorNakajima, Kentaro
dc.contributor.authorIshida, Yoshiki
dc.contributor.authorMiura, Daisuke
dc.contributor.authorHotta, Yasuhiro
dc.contributor.authorShinya, Akikazu
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code2607500
dc.converis.publication-id515744091
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/515744091
dc.date.accessioned2026-04-24T21:18:12Z
dc.description.abstract<p>This study evaluated the effects of various surface pretreatments using chairside air abrasion with water injection or laboratory sandblasting devices on the shear bond strength of resin luting agents to three CAD-CAM prosthetic materials: resin composites, glass ceramics, and zirconia. Pretreatments included air abrasion with water injection (29 µm or 53 µm alumina or bioactive glass powder), conventional sandblasting with 50 µm alumina, and hydrofluoric acid etching for glass ceramics. Specimens were prepared after embedding the blocks. Surface roughness was measured after pretreatment, and shear bond strength was tested following cementation. Failure modes were analyzed using an optical profilometer. Results showed that air abrasion with 50 µm alumina, whether using a chairside device with water injection or a laboratory sandblasting device, produced comparable bond strength. These findings suggest that chairside air abrasion with 50 µm alumina is a clinically viable alternative to laboratory sandblasting for surface treatment of CAD-CAM prosthetic materials.<br></p>
dc.identifier.eissn1881-1361
dc.identifier.jour-issn0287-4547
dc.identifier.urihttps://www.utupub.fi/handle/11111/59543
dc.identifier.urlhttps://doi.org/10.4012/dmj.2025-297
dc.identifier.urnURN:NBN:fi-fe2026042333273
dc.language.isoen
dc.okm.affiliatedauthorShinya, Akikazu
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherJapanese Society for Dental Materials and Devices
dc.publisher.countryJapanen_GB
dc.publisher.countryJapanifi_FI
dc.publisher.country-codeJP
dc.relation.articlenumber2025-297
dc.relation.doi10.4012/dmj.2025-297
dc.relation.ispartofjournalDental Materials Journal
dc.titleAir abrasion device versus sandblasting device for surface pretreatment of CAD-CAM prosthetic materials
dc.year.issued2026

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
advpub_2025-297.pdf
Size:
4.38 MB
Format:
Adobe Portable Document Format