Validation of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation support

dc.contributor.authorSiirala W
dc.contributor.authorNoponen T
dc.contributor.authorOlkkola KT
dc.contributor.authorVuori A
dc.contributor.authorKoivisto M
dc.contributor.authorHurme S
dc.contributor.authorAantaa R
dc.contributor.organizationfi=anestesiologia ja tehohoito|en=Anaesthesiology, Intensive Care|
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=biostatistiikka|en=Biostatistics|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.contributor.organization-code1.2.246.10.2458963.20.82197219338
dc.contributor.organization-code1.2.246.10.2458963.20.89365200099
dc.contributor.organization-code2607300
dc.contributor.organization-code2607301
dc.converis.publication-id3555154
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/3555154
dc.date.accessioned2022-10-28T13:33:02Z
dc.date.available2022-10-28T13:33:02Z
dc.description.abstractThe aim of this validation study was to assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo non-invasive ventilation (NIV). Oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured in twelve healthy volunteers. Respiratory quotient (RQ) and resting energy expenditure (REE) were then calculated from the measured VO2 and VCO2 values. During the measurement period the subjects were breathing spontaneously and ventilated using NIV. Two different sampling air flow values 40 and 80 l/min were used. The gas leakage from the measurement setup was assessed with a separate capnograph. The mean weight of the subjects was 93 kg. Their mean body mass index was 29 (range 22-40) kg/m(2). There was no statistically significant difference in the measured values for VO2, VCO2, RQ and REE during NIV-supported breathing and spontaneous breathing. The change of sampling air flow had no statistically significant effect on any of the above parameters. We found that REE can be accurately measured with an indirect calorimeter also during NIV-supported breathing and the change of sampling air flow does not distort the gas exchange measurement. A higher sampling air flow in indirect calorimetry decreases the possibility for air leakages in the measurement system and increases the reliability of REE measurement.
dc.format.pagerange37
dc.format.pagerange43
dc.identifier.jour-issn1387-1307
dc.identifier.olddbid182860
dc.identifier.oldhandle10024/165954
dc.identifier.urihttps://www.utupub.fi/handle/11111/40187
dc.identifier.urnURN:NBN:fi-fe2021042715228
dc.language.isoen
dc.okm.affiliatedauthorSiirala, Waltteri
dc.okm.affiliatedauthorNoponen, Tommi
dc.okm.affiliatedauthorOlkkola, Klaus
dc.okm.affiliatedauthorHurme, Saija
dc.okm.affiliatedauthorAantaa, Riku
dc.okm.discipline3111 Biomedicineen_GB
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3111 Biolääketieteetfi_FI
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSPRINGER HEIDELBERG
dc.publisher.countryNetherlandsen_GB
dc.publisher.countryAlankomaatfi_FI
dc.publisher.country-codeNL
dc.relation.doi10.1007/s10877-011-9331-z
dc.relation.ispartofjournalJournal of Clinical Monitoring and Computing
dc.relation.issue1
dc.relation.volume26
dc.source.identifierhttps://www.utupub.fi/handle/10024/165954
dc.titleValidation of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation support
dc.year.issued2012

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Manuscript_17082011.pdf
Size:
854.68 KB
Format:
Adobe Portable Document Format