Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study

dc.contributor.authorKuusisto Niina
dc.contributor.authorAbushahba Faleh
dc.contributor.authorSyrjänen Stina
dc.contributor.authorHuumonen Sisko
dc.contributor.authorVallittu Pekka
dc.contributor.authorNärhi Timo
dc.contributor.organizationfi=InFLAMES Lippulaiva|en=InFLAMES Flagship|
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.contributor.organization-code1.2.246.10.2458963.20.68445910604
dc.converis.publication-id181015018
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/181015018
dc.date.accessioned2025-08-27T21:32:50Z
dc.date.available2025-08-27T21:32:50Z
dc.description.abstract<p><strong>Objectives: </strong>Three-dimensional cone beam computed tomography (CBCT) imaging can be considered, especially in patients with complicated peri-implantitis (PI). Artifacts induced by dense materials are the drawback of CBCT imaging and the peri-implant bone condition may not be assessed reliably because the artifacts are present in the same area. This pilot study investigates the performance of the artifact reduction algorithm (ARA) of the Planmeca Viso G7 CBCT device (Planmeca, Helsinki, Finland) with three different implant materials and imaging parameters.</p><p><strong>Methods: </strong>Three pairs of dental implants consisting of titanium, zirconia, and fiber reinforced composite (FRC) were set into a pig mandible. A vertical defect simulating peri-implantitis bone loss was made on the buccal side of one of each implant. The defect was identified and measured by two observers and compared to the actual dimensions. In addition, the bone structure and the marginal cortex visibility between the implants were estimated visually.</p><p><strong>Results: </strong>The bone defect and its dimensions with the zirconia implant could not be identified in any image with or without the metal artifact reduction algorithm. The bone defect of titanium and FRC implants were identified with all three imaging parameters or even without ARA. The interobserver agreement between the two observers was almost perfect for all categories analyzed.</p><p><strong>Conclusion: </strong>Peri-implantitis defect of the zirconia implant and the peri-implant bone structure of the zirconia implants cannot be recognized reliably with any ARA levels, or any imaging parameters used with the Planmeca Viso G7. The need for ARA when imaging the peri-implant bone condition of the titanium and FRC implants may be unnecessary.</p>
dc.identifier.jour-issn0250-832X
dc.identifier.olddbid200592
dc.identifier.oldhandle10024/183619
dc.identifier.urihttps://www.utupub.fi/handle/11111/46098
dc.identifier.urlhttps://doi.org/10.1259/dmfr.20230252
dc.identifier.urnURN:NBN:fi-fe2025082785062
dc.language.isoen
dc.okm.affiliatedauthorSyrjänen, Stina
dc.okm.affiliatedauthorKuusisto, Niina
dc.okm.affiliatedauthorAbushahba, Faleh
dc.okm.affiliatedauthorVallittu, Pekka
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1259/dmfr.20230252
dc.relation.ispartofjournalDentomaxillofacial Radiology
dc.relation.issue8
dc.relation.volume52
dc.source.identifierhttps://www.utupub.fi/handle/10024/183619
dc.titleZirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
dmfr.20230252.pdf
Size:
3.22 MB
Format:
Adobe Portable Document Format