Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
| dc.contributor.author | Pietiläinen Sakari | |
| dc.contributor.author | Linnovaara Axel | |
| dc.contributor.author | Venäläinen Mikko S | |
| dc.contributor.author | Mäntymäki Heikki | |
| dc.contributor.author | Laaksonen Inari | |
| dc.contributor.author | Lankinen Petteri | |
| dc.contributor.author | Mäkelä Keijo T | |
| dc.contributor.organization | fi=Turun biotiedekeskus|en=Turku Bioscience Centre| | |
| dc.contributor.organization | fi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology| | |
| dc.contributor.organization | fi=tyks, vsshp|en=tyks, varha| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.18586209670 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.90281651480 | |
| dc.contributor.organization-code | 2607310 | |
| dc.converis.publication-id | 175280095 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/175280095 | |
| dc.date.accessioned | 2022-10-27T12:12:22Z | |
| dc.date.available | 2022-10-27T12:12:22Z | |
| dc.description.abstract | <p>Background and purpose<br></p><p>We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA.<br></p><p>Patients and methods<br></p><p>ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan–Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal<br>ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor).<br></p><p>Results<br></p><p>Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years.<br></p><p>Interpretation<br></p><p>WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients.<br></p> | |
| dc.format.pagerange | 444 | |
| dc.format.pagerange | 450 | |
| dc.identifier.eissn | 1745-3674 | |
| dc.identifier.jour-issn | 1745-3674 | |
| dc.identifier.olddbid | 173905 | |
| dc.identifier.oldhandle | 10024/156999 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/31710 | |
| dc.identifier.url | https://doi.org/10.2340/17453674.2022.2510 | |
| dc.identifier.urn | URN:NBN:fi-fe2022081153803 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Pietiläinen, Sakari | |
| dc.okm.affiliatedauthor | Venäläinen, Mikko | |
| dc.okm.affiliatedauthor | Laaksonen, Inari | |
| dc.okm.affiliatedauthor | Lankinen, Petteri | |
| dc.okm.affiliatedauthor | Mäkelä, Keijo | |
| dc.okm.affiliatedauthor | Dataimport, tyks, vsshp | |
| dc.okm.discipline | 3126 Surgery, anesthesiology, intensive care, radiology | en_GB |
| dc.okm.discipline | 3126 Kirurgia, anestesiologia, tehohoito, radiologia | fi_FI |
| dc.okm.internationalcopublication | not an international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | Medical Journals Sweden AB | |
| dc.publisher.country | United Kingdom | en_GB |
| dc.publisher.country | Britannia | fi_FI |
| dc.publisher.country-code | GB | |
| dc.relation.doi | 10.2340/17453674.2022.2510 | |
| dc.relation.ispartofjournal | Acta Orthopaedica | |
| dc.relation.volume | 93 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/156999 | |
| dc.title | Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty | |
| dc.year.issued | 2022 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- PietiläinenEtAl2022Median10-YearWholeBloodMetalIon.pdf
- Size:
- 839.13 KB
- Format:
- Adobe Portable Document Format