Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty

dc.contributor.authorPietiläinen Sakari
dc.contributor.authorLinnovaara Axel
dc.contributor.authorVenäläinen Mikko S
dc.contributor.authorMäntymäki Heikki
dc.contributor.authorLaaksonen Inari
dc.contributor.authorLankinen Petteri
dc.contributor.authorMäkelä Keijo T
dc.contributor.organizationfi=Turun biotiedekeskus|en=Turku Bioscience Centre|
dc.contributor.organizationfi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.18586209670
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.contributor.organization-code2607310
dc.converis.publication-id175280095
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/175280095
dc.date.accessioned2022-10-27T12:12:22Z
dc.date.available2022-10-27T12:12:22Z
dc.description.abstract<p>Background and purpose<br></p><p>We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA.<br></p><p>Patients and methods<br></p><p>ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan–Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal<br>ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor).<br></p><p>Results<br></p><p>Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years.<br></p><p>Interpretation<br></p><p>WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients.<br></p>
dc.format.pagerange444
dc.format.pagerange450
dc.identifier.eissn1745-3674
dc.identifier.jour-issn1745-3674
dc.identifier.olddbid173905
dc.identifier.oldhandle10024/156999
dc.identifier.urihttps://www.utupub.fi/handle/11111/31710
dc.identifier.urlhttps://doi.org/10.2340/17453674.2022.2510
dc.identifier.urnURN:NBN:fi-fe2022081153803
dc.language.isoen
dc.okm.affiliatedauthorPietiläinen, Sakari
dc.okm.affiliatedauthorVenäläinen, Mikko
dc.okm.affiliatedauthorLaaksonen, Inari
dc.okm.affiliatedauthorLankinen, Petteri
dc.okm.affiliatedauthorMäkelä, Keijo
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMedical Journals Sweden AB
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.2340/17453674.2022.2510
dc.relation.ispartofjournalActa Orthopaedica
dc.relation.volume93
dc.source.identifierhttps://www.utupub.fi/handle/10024/156999
dc.titleMedian 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
dc.year.issued2022