Repeated metal ion measurements and long-term outcome of Durom/MMC total hip arthroplasty

dc.contributor.authorPietiläinen Sakari
dc.contributor.authorSmedberg Erno
dc.contributor.authorLaaksonen Inari
dc.contributor.authorVenäläinen Mikko S
dc.contributor.authorLankinen Petteri
dc.contributor.authorMäkelä Keijo T
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.contributor.organization-code2607310
dc.converis.publication-id175032770
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/175032770
dc.date.accessioned2022-10-28T13:13:20Z
dc.date.available2022-10-28T13:13:20Z
dc.description.abstract<p><strong>Background and purpose</strong> — Data regarding long-term behavior of metal ion levels in metal-on-metal total hip arthroplasty (MoM THA) patients is scarce. Therefore, we assessed whether there is any change in whole blood (WB) chromium (Cr), and cobalt (Co) ion measurements in Durom and MMC MoM THA patients over time. The secondary aim was to report the clinical outcomes using these devices in a single district.</p><p><strong>Patients and methods</strong> — Durom and MMC cups were used in 249 MoM THAs from 2005 to 2011 in our district. Median follow-up time was 12 years for Durom THA (interquartile range [IQR] = 3) and 9 years for MMC THA (IQR = 1). A random coefficient model was used to compare individual differences in repeated WB Cr and Co ion measurements. The Kaplan–Meier estimator was used to analyze implant survival with any reason for revision as the endpoint.</p><p><strong>Results</strong> — Geometric means of Cr in Durom THA and MMC THA patients decreased from 2.2 ppb (geometric standard deviation [SD] = 1.9) to 1.5 ppb (geometric SD = 2.5, p< 0.001) and from 1.8 ppb (geometric SD = 1.8) to 1.1 ppb (geometric SD = 2.8, p = 0.01) respectively. The geometric means of Co values remained unchanged. The 10-year survival of Durom THA was 82%, and that of MMC THA 89% for any revision reason as endpoint.</p><p><strong>Interpretation</strong> — WB Cr levels decreased over time, and Co levels remained unchanged at long-term follow-up. Despite this we recommend continuing the follow-up of these devices due to relatively low implant survival. </p>
dc.format.pagerange241
dc.format.pagerange248
dc.identifier.eissn1745-3674
dc.identifier.jour-issn1745-3674
dc.identifier.olddbid180589
dc.identifier.oldhandle10024/163683
dc.identifier.urihttps://www.utupub.fi/handle/11111/31858
dc.identifier.urlhttps://doi.org/10.2340/17453674.2022.1444
dc.identifier.urnURN:NBN:fi-fe2022081154500
dc.language.isoen
dc.okm.affiliatedauthorPietiläinen, Sakari
dc.okm.affiliatedauthorLaaksonen, Inari
dc.okm.affiliatedauthorVenäläinen, Mikko
dc.okm.affiliatedauthorLankinen, Petteri
dc.okm.affiliatedauthorMäkelä, Keijo
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMedical Journals Sweden
dc.publisher.countrySwedenen_GB
dc.publisher.countryRuotsifi_FI
dc.publisher.country-codeSE
dc.relation.doi10.2340/17453674.2022.1444
dc.relation.ispartofjournalActa Orthopaedica
dc.relation.volume93
dc.source.identifierhttps://www.utupub.fi/handle/10024/163683
dc.titleRepeated metal ion measurements and long-term outcome of Durom/MMC total hip arthroplasty
dc.year.issued2022

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
15680 PIETILÄINEN et al. Repeated metal ion measurements and long-term outcome of Durom_MMC total hip arthroplasty.pdf
Size:
894.64 KB
Format:
Adobe Portable Document Format