Multiplex Point-of-Care Tests for the Determination of Antibodies after Acellular Pertussis Vaccination

dc.contributor.authorAapo Knuutila
dc.contributor.authorCarita Rautanen
dc.contributor.authorJussi Mertsola
dc.contributor.authorQiushui He
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.converis.publication-id46493362
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/46493362
dc.date.accessioned2022-10-28T14:17:00Z
dc.date.available2022-10-28T14:17:00Z
dc.description.abstract<p>Most of the current serological diagnosis of pertussis is based on pertussis toxin (PT) IgG antibodies and does not differentiate between vaccination and infection-induced antibodies. PT is included in all of acellular pertussis vaccines available in the world. Multiplex testing of non-vaccine antigen-related antibodies has the potential to improve the diagnostic outcome of these assays. In this study, we developed a quantitatively spatial multiplex lateral flow immunoassay (LFIA) for the detection of IgG antibodies directed against PT, pertactin (PRN), and filamentous hemagglutinin (FHA). The assay was evaluated with serum samples with varying anti-PT, anti-PRN, and anti-FHA IgG levels and the result was compared to those obtained with standardized ELISA. The developed assay showed good specificity with PT and PRN antibodies and semiquantification throughout the antigen combinations. This exploratory study indicates that the multiplex LFIA is specific and sensitive, and a similar test platform with alternative antigens could be suitable for new type of pertussis serology.</p>
dc.identifier.eissn2075-4418
dc.identifier.jour-issn2075-4418
dc.identifier.olddbid187362
dc.identifier.oldhandle10024/170456
dc.identifier.urihttps://www.utupub.fi/handle/11111/42973
dc.identifier.urnURN:NBN:fi-fe2021042825901
dc.language.isoen
dc.okm.affiliatedauthorKnuutila, Aapo
dc.okm.affiliatedauthorMertsola, Jussi
dc.okm.affiliatedauthorHe, Qiushui
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3111 Biomedicineen_GB
dc.okm.discipline3111 Biolääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMDPI AG
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.doi10.3390/diagnostics10040187
dc.relation.ispartofjournalDiagnostics
dc.relation.issue4
dc.relation.volume10
dc.source.identifierhttps://www.utupub.fi/handle/10024/170456
dc.titleMultiplex Point-of-Care Tests for the Determination of Antibodies after Acellular Pertussis Vaccination
dc.year.issued2020