Composition of cardiac troponin release differs after marathon running and myocardial infarction

dc.contributor.authorAiraksinen, K. E. Juhani
dc.contributor.authorPaana, Tuomas
dc.contributor.authorVasankari, Tuija
dc.contributor.authorSalonen, Selma
dc.contributor.authorTuominen, Tuulia
dc.contributor.authorLinko-Parvinen, Anna
dc.contributor.authorPallari, Hanna-Mari
dc.contributor.authorHellman, Tapio
dc.contributor.authorTeppo, Konsta
dc.contributor.authorHeinonen, Olli J
dc.contributor.authorJaakkola, Samuli
dc.contributor.authorWittfooth, Saara
dc.contributor.organizationfi=biotekniikka|en=Biotechnology|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.69079168212
dc.contributor.organization-code1.2.246.10.2458963.20.98373201676
dc.converis.publication-id470972278
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/470972278
dc.date.accessioned2025-08-28T03:25:17Z
dc.date.available2025-08-28T03:25:17Z
dc.description.abstract<p>OBJECTIVES: Elevations of cardiac troponin T (cTnT) levels are common after strenuous exercise. We assessed whether the composition of cTnT release after marathon race differs from that of acute myocardial infarction (MI).<br></p><p>METHODS: Troponin composition was analysed in plasma samples taken from 45 runners after marathon race and from 84 patients with type 1 MI. The concentration of long cTnT (intact and mildly fragmented cTnT) was measured with a novel upconversion luminescence immunoassay, total cTnT with a commercial high-sensitivity cTnT assay, and the ratio of long to total cTnT (troponin ratio) was determined as a measure of troponin fragmentation.<br></p><p>RESULTS: Total cTnT exceeded the upper reference limit (>14 ng/L) in 37 (82%) runners. Troponin ratio was lower in runners ((IQR) 0.17 (0.11-0.24) vs 0.62 (0.29-0.96), p<0.001). With increasing troponin release the troponin ratio decreased (r=-0.497, p<0.001) in marathon runners and the concentration of long cTnT remained in all runners below 8.4 ng/L. In contrast to marathon runners, troponin ratio increased (r=0.565, p<0.001) with the increase of cTnT release in patients with MI. The median total and long cTnT concentrations were lower in marathon runners than in patients with MI (25 ng/L vs 835 ng/L and 4.1 vs 385 ng/L, p<0.001 for both).<br></p><p>CONCLUSION: In contrast to type 1 MI, only a small fraction of circulating cTnT exists as intact cTnT or long molecular forms after strenuous exercise and the difference in troponin composition is more pronounced in runners with higher troponin release.<br></p><p>TRIAL REGISTRATION NUMBER: NCT06000930.<br></p>
dc.identifier.eissn2053-3624
dc.identifier.jour-issn2398-595X
dc.identifier.olddbid210649
dc.identifier.oldhandle10024/193676
dc.identifier.urihttps://www.utupub.fi/handle/11111/54451
dc.identifier.urlhttps://doi.org/10.1136/openhrt-2024-002954
dc.identifier.urnURN:NBN:fi-fe2025082786714
dc.language.isoen
dc.okm.affiliatedauthorAiraksinen, Juhani
dc.okm.affiliatedauthorPaana, Tuomas
dc.okm.affiliatedauthorVasankari, Tuija
dc.okm.affiliatedauthorSalonen, Selma
dc.okm.affiliatedauthorTuominen, Tuulia
dc.okm.affiliatedauthorLinko-Parvinen, Anna-Maria
dc.okm.affiliatedauthorHellman, Tapio
dc.okm.affiliatedauthorTeppo, Konsta
dc.okm.affiliatedauthorHeinonen, Olli
dc.okm.affiliatedauthorJaakkola, Samuli
dc.okm.affiliatedauthorWittfooth, Saara
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBMJ
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumbere002954
dc.relation.doi10.1136/openhrt-2024-002954
dc.relation.ispartofjournalOpen Heart
dc.relation.issue2
dc.relation.volume11
dc.source.identifierhttps://www.utupub.fi/handle/10024/193676
dc.titleComposition of cardiac troponin release differs after marathon running and myocardial infarction
dc.year.issued2024

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
e002954.full.pdf
Size:
657.39 KB
Format:
Adobe Portable Document Format