Light-curing of orthodontic bracket adhesive by transillumination through dentine and enamel
| dc.contributor.author | Erika Mäkinen | |
| dc.contributor.author | Lippo Lassila | |
| dc.contributor.author | Juha Varrela | |
| dc.contributor.author | Pekka Vallittu | |
| dc.contributor.organization | fi=hammaslääketieteen laitos|en=Institute of Dentistry| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.64787032594 | |
| dc.converis.publication-id | 43858066 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/43858066 | |
| dc.date.accessioned | 2022-10-28T13:24:52Z | |
| dc.date.available | 2022-10-28T13:24:52Z | |
| dc.description.abstract | <p>Bonding properties of light-curing adhesive cured by transillumination through the tooth were compared to those achieved by the conventional technique. The study analyzed the degree of cure (DC%), debonding force (DF) and adhesive remnant index (ARI) when light was transmitted through dental hard tissues. Slices of dentin and enamel of 1 mm in thickness were combined with total thicknesses of 3 or 4 mm to simulate tooth structure without the pulp tissue. DC% with curing time of 20 s, 40 s and 60 s and irradiance power was measured for each group (n ¼ 5). Brackets were bonded using transillumination on extracted incisors (n ¼ 6) and premolars (n ¼ 10), and DF was measured and ARI was scored. No statistical difference was found in light transmission between the simulated samples and incisors (p > .05). Increasing the curing time from 40 s to 60 s enhanced the DC% only in premolars (p < .05). An adequate DF was achieved through transillumination both in incisors and premolars, but in premolars, the DC% remained low compared to conventionally cured brackets. Most of the bracket failures resulted from weak bracket-adhesive bond.<br /></p> | |
| dc.identifier.eissn | 2641-5275 | |
| dc.identifier.jour-issn | 2641-5275 | |
| dc.identifier.olddbid | 181921 | |
| dc.identifier.oldhandle | 10024/165015 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/38984 | |
| dc.identifier.url | 10.1080/26415275.2019.1632709 | |
| dc.identifier.urn | URN:NBN:fi-fe2021042826927 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Mäkinen, Erika | |
| dc.okm.affiliatedauthor | Lassila, Lippo | |
| dc.okm.affiliatedauthor | Varrela, Juha | |
| dc.okm.affiliatedauthor | Vallittu, Pekka | |
| dc.okm.discipline | 313 Dentistry | en_GB |
| dc.okm.discipline | 313 Hammaslääketieteet | fi_FI |
| dc.okm.internationalcopublication | not an international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.relation.doi | 10.1080/26415275.2019.1632709 | |
| dc.relation.ispartofjournal | Biomaterial Investigations in Dentistry | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/165015 | |
| dc.title | Light-curing of orthodontic bracket adhesive by transillumination through dentine and enamel | |
| dc.year.issued | 2019 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Light curing of orthodontic bracket adhesive by transillumination through dentine and enamel.pdf
- Size:
- 1.48 MB
- Format:
- Adobe Portable Document Format
- Description:
- Publisher's PDF (CC BY)