Effect of Accelerated Aging on Some Mechanical Properties and Wear of Different Commercial Dental Resin Composites

dc.contributor.authorOja Jonne
dc.contributor.authorLassila Lippo
dc.contributor.authorVallittu Pekka K
dc.contributor.authorGaroushi Sufyan
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.converis.publication-id56624434
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/56624434
dc.date.accessioned2022-10-27T11:51:10Z
dc.date.available2022-10-27T11:51:10Z
dc.description.abstract<p>The aim of current in vitro research was to determine the effect of hydrothermal accelerated aging on the mechanical properties and wear of different commercial dental resin composites (RCs). In addition, the effect of expiration date of the composite prior its use was also evaluated. Five commercially available RCs were studied: Conventional RCs (Filtek Supreme XTE, G-aenial Posterior, Denfil, and >3y expired Supreme XTE), bulk-fill RC (Filtek Bulk Fill), and short fiber-reinforced RC (everX Posterior). Three-point flexural test was used for determination of ultimate flexural strength (<i>n</i> = 8). A vickers indenter was used for testing surface microhardness. A wear test was conducted with 15,000 chewing cycles using a dual-axis chewing simulator. Wear pattern was analyzed by a three-dimensional (3D) noncontact optical profilometer. Degree of C=C bond conversion of monomers was determined by FTIR-spectrometry. The specimens were either dry stored for 48 h (37 °C) or boiled (100 °C) for 16 h before testing. Scanning electron microscopy (SEM) was used to evaluate the microstructure of each material. Data were analyzed using ANOVA (<i>p</i> = 0.05). Hydrothermal aging had no significant effects on the surface wear and microhardness of tested RCs (<i>p</i> > 0.05). While flexural strength significantly decreased after aging (<i>p</i> < 0.05), except for G-aenial Posterior, which showed no differences. The lowest average wear depth was found for Filtek Bulk Fill (29 µm) (<i>p</i> < 0.05), while everX Posterior and Denfil showed the highest wear depth values (40, 39 µm) in both conditions. Passing the expiration date for 40 months did not affect the flexural strength and wear of tested RC. SEM demonstrated a significant number of small pits on Denfil's surface after aging. It was concluded that the effect of accelerated aging may have caused certain weakening of the RC of some brands, whereas no effect was found with one brand of RC. Thus, the accelerated aging appeared to be more dependent on material and tested material property.<br></p>
dc.identifier.jour-issn1996-1944
dc.identifier.olddbid172293
dc.identifier.oldhandle10024/155387
dc.identifier.urihttps://www.utupub.fi/handle/11111/30035
dc.identifier.urnURN:NBN:fi-fe2021093047930
dc.language.isoen
dc.okm.affiliatedauthorGaroushi, Sufyan
dc.okm.affiliatedauthorLassila, Lippo
dc.okm.affiliatedauthorVallittu, Pekka
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMDPI
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.articlenumber2769
dc.relation.doi10.3390/ma14112769
dc.relation.ispartofjournalMaterials
dc.relation.issue11
dc.relation.volume14
dc.source.identifierhttps://www.utupub.fi/handle/10024/155387
dc.titleEffect of Accelerated Aging on Some Mechanical Properties and Wear of Different Commercial Dental Resin Composites
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
materials-14-02769-v2 (1).pdf
Size:
3.91 MB
Format:
Adobe Portable Document Format
Description:
Publisher's version