Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs

dc.contributor.authorBallo H
dc.contributor.authorTarkia M
dc.contributor.authorHaavisto M
dc.contributor.authorStark C
dc.contributor.authorStrandberg M
dc.contributor.authorVahasilta T
dc.contributor.authorSaunavaara V
dc.contributor.authorTolvanen T
dc.contributor.authorTeras M
dc.contributor.authorHynninen VV
dc.contributor.authorSavunen T
dc.contributor.authorRoivainen A
dc.contributor.authorKnuuti J
dc.contributor.authorSaraste A
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=anestesiologia ja tehohoito|en=Anaesthesiology, Intensive Care|
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=kirurgia|en=Surgery|
dc.contributor.organizationfi=kliininen fysiologia ja isotooppilääketiede|en=Clinical Physiology and Isotope Medicine|
dc.contributor.organizationfi=lääketieteellinen tiedekunta|en=Faculty of Medicine|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=sydäntutkimuskeskus|en=Cardiovascular Medicine (CAPC)|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.13290506867
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.contributor.organization-code1.2.246.10.2458963.20.82197219338
dc.contributor.organization-code2607000
dc.contributor.organization-code2607004
dc.contributor.organization-code2607309
dc.contributor.organization-code2607318
dc.contributor.organization-code2607322
dc.contributor.organization-code2609810
dc.converis.publication-id19062462
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/19062462
dc.date.accessioned2022-10-28T13:55:32Z
dc.date.available2022-10-28T13:55:32Z
dc.description.abstractBackground: We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI).Methods: Male farm pigs with surgical occlusion of the left anterior descending coronary artery (n = 9) or sham operation (n = 5) had transthoracic echocardiography and cardiac-CT 3 months after surgery. We measured length of the LV in parasternal long axis view, and both systolic and diastolic LV areas in parasternal short axis views at the level of mitral valve, papillary muscles and apex. Volumes and EF of the LV were calculated using Simpson's method of discs (tri-plane area) or Cylinder-hemiellipsoid method (single plane area).Results: The pigs with coronary occlusion had anterior MI scars and reduced EF (average EF 42 +/- 10%) by CT. Measurements of LV volumes and EF were reproducible by echocardiography. Compared with CT, end-diastolic volume (EDV) measured by echocardiography showed good correlation and agreement using either Simpson's method (r = 0.90; mean difference -2, 95% CI -47 to 43 mL) or Cylinder-hemiellipsoid method (r = 0.94; mean difference 3, 95% CI -44 to 49 mL). Furthermore, End-systolic volume (ESV) measured by echocardiography showed also good correlation and agreement using either Simpson's method (r = 0.94; mean difference 12 ml, 95% CI: -16 to 40) or Cylinder-hemiellipsoid method (r = 0.97; mean difference: 13 ml, 95% CI: -8 to 33). EF was underestimated using either Simpson's method (r = 0.78; mean difference -6, 95% CI -11 to 1%) or Cylinder-hemiellipsoid method (r = 0.74; mean difference -4, 95% CI-10 to 2%).Conclusion: Our results indicate that measurement of LV volumes may be accurate, but EF is underestimated using either three or single parasternal short axis planes by echocardiography in a large animal model of chronic MI.
dc.identifier.jour-issn1476-7120
dc.identifier.olddbid185218
dc.identifier.oldhandle10024/168312
dc.identifier.urihttps://www.utupub.fi/handle/11111/41118
dc.identifier.urnURN:NBN:fi-fe2021042716622
dc.language.isoen
dc.okm.affiliatedauthorBallo, Haitham
dc.okm.affiliatedauthorTarkia, Miikka
dc.okm.affiliatedauthorHaavisto, Matti
dc.okm.affiliatedauthorStark, Christoffer
dc.okm.affiliatedauthorStrandberg, Marjatta
dc.okm.affiliatedauthorVähäsilta, Tommi
dc.okm.affiliatedauthorTolvanen, Tuula
dc.okm.affiliatedauthorTeräs, Mika
dc.okm.affiliatedauthorHynninen, Ville-Veikko
dc.okm.affiliatedauthorSavunen, Timo
dc.okm.affiliatedauthorRoivainen, Anne
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorSaraste, Antti
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBIOMED CENTRAL LTD
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumberARTN 1
dc.relation.doi10.1186/s12947-016-0093-0
dc.relation.ispartofjournalCardiovascular Ultrasound
dc.relation.volume15
dc.source.identifierhttps://www.utupub.fi/handle/10024/168312
dc.titleAccuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
dc.year.issued2017

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
art%3A10.1186%2Fs12947-016-0093-0.pdf
Size:
2.53 MB
Format:
Adobe Portable Document Format
Description:
Publisher's version