NEMA NU 4-2008 and in vivo imaging performance of RAYCAN trans-PET/CT X5 small animal imaging system

dc.contributor.authorJ Teuho
dc.contributor.authorC Han
dc.contributor.authorL Riehakainen
dc.contributor.authorA Honkaniemi
dc.contributor.authorM Tirri
dc.contributor.authorH Liljenbäck
dc.contributor.authorJ Virta
dc.contributor.authorS Gu
dc.contributor.authorS Liu
dc.contributor.authorL Wan
dc.contributor.authorM Teräs
dc.contributor.authorA Roivainen
dc.contributor.authorQ Xie
dc.contributor.authorJ Knuuti
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.contributor.organization-code2609810
dc.converis.publication-id41260358
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/41260358
dc.date.accessioned2022-10-27T12:19:24Z
dc.date.available2022-10-27T12:19:24Z
dc.description.abstractThe RAYCAN Trans-PET/CT X5 is a preclinical positron emission tomography and computed tomography (PET/CT) system intended for in vivo imaging of rats and mice, featuring all-digital readout electronics for PET data acquisition.The National Electrical Manufacturers Association (NEMA) NU 4-2008 performance evaluation was conducted on the RAYCAN Trans-PET/CT X5 in addition to assessing in vivo imaging performance of the system on live animals. The performance characteristics of the system were evaluated, including system spatial resolution, count rate performance, sensitivity and image quality. The system imaging performance is assessed in dynamic in vivo PET imaging.The system resolution defined as full width half maximum (FWHM) was 2.07 mm, 2.11 mm and 1.31 mm for the tangential, radial and axial resolution, respectively, at the center of the field of view. The peak noise equivalent count rate (NECR) values measured were 61 kcps at 0.19 MBq ml(-1) for the rat size phantom and 126 kcps at 1.53 MBq ml(-1) for the mouse size phantom. Scatter fractions were 24% and 14% for the rat and mouse phantom. The measured peak sensitivity of the system was 1.70%. Image quality in static imaging was deemed sufficient based on the image quality phantom study, with average activity concentration of 155 +/- 8.6 kBq ml(-1) and image uniformity of 5.57% when using two-dimensional filtered backprojection algorithm (2D-FBP). Rods in the image quality phantom were visualized easily up to 2 mm in size. In dynamic in vivo PET imaging, time-activity-curves from several regions were successfully measured, characterizing the radioactivity distribution in myocardial blood pool, liver, left ventricle and the lung.In conclusion, the RAYCAN Trans-PET/CT X5 system can be considered a suitable option for basic imaging needs in preclinical imaging.
dc.identifier.eissn1361-6560
dc.identifier.jour-issn0031-9155
dc.identifier.olddbid174727
dc.identifier.oldhandle10024/157821
dc.identifier.urihttps://www.utupub.fi/handle/11111/34846
dc.identifier.urnURN:NBN:fi-fe2021042823171
dc.language.isoen
dc.okm.affiliatedauthorTeuho, Jarmo
dc.okm.affiliatedauthorHan, Chunlei
dc.okm.affiliatedauthorRiehakainen, Leon
dc.okm.affiliatedauthorHonkaniemi, Aake
dc.okm.affiliatedauthorTirri, Marko
dc.okm.affiliatedauthorLiljenbäck, Heidi
dc.okm.affiliatedauthorVirta, Jenni
dc.okm.affiliatedauthorTeräs, Mika
dc.okm.affiliatedauthorRoivainen, Anne
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherIOP PUBLISHING LTD
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumber115014
dc.relation.doi10.1088/1361-6560/ab1856
dc.relation.ispartofjournalPhysics in Medicine and Biology
dc.relation.issue11
dc.relation.volume64
dc.source.identifierhttps://www.utupub.fi/handle/10024/157821
dc.titleNEMA NU 4-2008 and in vivo imaging performance of RAYCAN trans-PET/CT X5 small animal imaging system
dc.year.issued2019

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
PMB-108134 Clean Final Version Teuho R2.pdf
Size:
759.36 KB
Format:
Adobe Portable Document Format
Description:
Final draft