System evaluation of automated production and inhalation of O-15-labeled gaseous radiopharmaceuticals for the rapid O-15-oxygen PET examinations

dc.contributor.authorSatoshi Iguchi
dc.contributor.authorTetsuaki Moriguchi
dc.contributor.authorMakoto Yamazaki
dc.contributor.authorYuki Hori
dc.contributor.authorKazuhiro Koshino
dc.contributor.authorKazunori Toyoda
dc.contributor.authorJarmo Teuho
dc.contributor.authorSaeka Shimochi
dc.contributor.authorYusuke Terakawa
dc.contributor.authorTetsuya Fukuda
dc.contributor.authorJun C. Takahashi
dc.contributor.authorJyoji Nakagawara
dc.contributor.authorShigehiko Kanaya
dc.contributor.authorHidehiro Iida
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.converis.publication-id38068166
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/38068166
dc.date.accessioned2022-10-28T13:56:54Z
dc.date.available2022-10-28T13:56:54Z
dc.description.abstract<p>Background(15)O-oxygen inhalation PET is unique in its ability to provide fundamental information regarding cerebral hemodynamics and energy metabolism in man. However, the use of O-15-oxygen has been limited in a clinical environment largely attributed to logistical complexity, in relation to a long study period, and the need to produce and inhale three sets of radiopharmaceuticals. Despite the recent works that enabled shortening of the PET examination period, radiopharmaceutical production has still been a limiting factor. This study was aimed to evaluate a recently developed radiosynthesis/inhalation system that automatically supplies a series of O-15-labeled gaseous radiopharmaceuticals of (CO)-O-15, O-15(2), and (CO2)-O-15 at short intervals.MethodsThe system consists of a radiosynthesizer which produces (CO)-O-15, O-15(2), and (CO2)-O-15; an inhalation controller; and an inhalation/scavenging unit. All three parts are controlled by a common sequencer, enabling automated production and inhalation at intervals less than 4.5min. The gas inhalation/scavenging unit controls to sequentially supply of qualified radiopharmaceuticals at given radioactivity for given periods at given intervals. The unit also scavenges effectively the non-inhaled radioactive gases. Performance and reproducibility are evaluated.ResultsUsing an O-15-dedicated cyclotron with deuteron of 3.5MeV at 40A, (CO)-O-15, O-15(2), and (CO2)-O-15 were sequentially produced at a constant rate of 1400, 2400, and 2000MBq/min, respectively. Each of radiopharmaceuticals were stably inhaled at <4.5min intervals with negligible contamination from the previous supply. The two-hole two-layered face mask with scavenging device minimized the gaseous radioactivity surrounding subject's face, while maintaining the normocapnia during examination periods. Quantitative assessment of net administration doses could be assessed using a pair of radio-detectors at inlet and scavenging tubes, as 541149, 320 +/- 103, 523 +/- 137MBq corresponding to 2-min supply of 2574 +/- 255MBq for (CO)-O-15, and 1-min supply of 2220 +/- 766 and 1763 +/- 174 for O-15(2) and (CO2)-O-15, respectively.Conclusions The present system allowed for automated production and inhalation of series of O-15-labeled radiopharmaceuticals as required in the rapid O-15-Oxygen PET protocol. The production and inhalation were reproducible and improved logistical complexity, and thus the use of O-15-oxygen might have become practically applicable in clinical environments.<br /></p>
dc.format.pagerange37
dc.identifier.eissn2197-7364
dc.identifier.jour-issn2197-7364
dc.identifier.olddbid185364
dc.identifier.oldhandle10024/168458
dc.identifier.urihttps://www.utupub.fi/handle/11111/42201
dc.identifier.urlhttps://www.ncbi.nlm.nih.gov/pubmed/30569426
dc.identifier.urnURN:NBN:fi-fe2021042824392
dc.language.isoen
dc.okm.affiliatedauthorTeuho, Jarmo
dc.okm.affiliatedauthorShimochi, Saeka
dc.okm.affiliatedauthorIida, Hidehiro
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline319 Forensic science and other medical sciencesen_GB
dc.okm.discipline319 Oikeuslääketiede ja muut lääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisher.countryGermanyen_GB
dc.publisher.countrySaksafi_FI
dc.publisher.country-codeDE
dc.relation.doi10.1186/s40658-018-0236-5
dc.relation.ispartofjournalEJNMMI Physics
dc.relation.volume5
dc.source.identifierhttps://www.utupub.fi/handle/10024/168458
dc.titleSystem evaluation of automated production and inhalation of O-15-labeled gaseous radiopharmaceuticals for the rapid O-15-oxygen PET examinations
dc.year.issued2018

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s40658-018-0236-5.pdf
Size:
2.72 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF