Sensitivity, specificity, inclusivity and exclusivity of the updated Aptima Combo 2 assay, which provides detection coverage of the new diagnostic-escapeChlamydia trachomatisvariants

dc.contributor.authorMagnus Unemo
dc.contributor.authorMarit Hansen
dc.contributor.authorRonza Hadad
dc.contributor.authorMirja Puolakkainen
dc.contributor.authorHenrik Westh
dc.contributor.authorKaisu Rantakokko-Jalava
dc.contributor.authorCarina Thilesen
dc.contributor.authorMichelle J. Cole
dc.contributor.authorIryna Boiko
dc.contributor.authorPham T. Lan
dc.contributor.authorDaniel Golparian
dc.contributor.authorShin Ito
dc.contributor.authorMartin Sundqvist
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.converis.publication-id49344453
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/49344453
dc.date.accessioned2022-10-28T14:18:23Z
dc.date.available2022-10-28T14:18:23Z
dc.description.abstractBackground Four new variants ofChlamydia trachomatis(nvCTs), detected in several countries, cause false-negative or equivocal results using the Aptima Combo 2 assay (AC2; Hologic). We evaluated the clinical sensitivity and specificity, as well as the analytical inclusivity and exclusivity of the updated AC2 for the detection of CT andNeisseria gonorrhoeae(NG) on the automated Panther system (Hologic). <div>Methods We examined 1004 clinical AC2 samples and 225 analytical samples spiked with phenotypically and/or genetically diverse NG and CT strains, and other potentially cross-reacting microbial species. The clinical AC2 samples included CT wild type (WT)-positive (n = 488), all four described AC2 diagnostic-escape nvCTs (n = 170), NG-positive (n = 214), and CT/NG-negative (n = 202) specimens. </div><div>Results All nvCT-positive samples (100%) and 486 (99.6%) of the CT WT-positive samples were positive in the updated AC2. All NG-positive, CT/NG-negative,Trichomonas vaginalis(TV)-positive, bacterial vaginosis-positive, andCandida-positive AC2 specimens gave correct results. The clinical sensitivity and specificity of the updated AC2 for CT detection was 99.7 and 100%, respectively, and for NG detection was 100% for both. Examining spiked samples, the analytical inclusivity and exclusivity were 100%, i.e., in clinically relevant concentrations of spiked microbe. </div><div>Conclusions The updated AC2, including two CT targets and one NG target, showed a high sensitivity, specificity, inclusivity and exclusivity for the detection of CT WT, nvCTs, and NG. The updated AC2 on the fully automated Panther system offers a simple, rapid, high-throughput, sensitive, and specific diagnosis of CT and NG, which can easily be combined with detection ofMycoplasma genitaliumand TV.</div>
dc.identifier.eissn1471-2334
dc.identifier.jour-issn1471-2334
dc.identifier.olddbid187494
dc.identifier.oldhandle10024/170588
dc.identifier.urihttps://www.utupub.fi/handle/11111/43067
dc.identifier.urnURN:NBN:fi-fe2021042826017
dc.language.isoen
dc.okm.affiliatedauthorRantakokko-Jalava, Kaisu
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3111 Biomedicineen_GB
dc.okm.discipline3111 Biolääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBMC
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumberARTN 419
dc.relation.doi10.1186/s12879-020-05148-7
dc.relation.ispartofjournalBMC Infectious Diseases
dc.relation.issue1
dc.relation.volume20
dc.source.identifierhttps://www.utupub.fi/handle/10024/170588
dc.titleSensitivity, specificity, inclusivity and exclusivity of the updated Aptima Combo 2 assay, which provides detection coverage of the new diagnostic-escapeChlamydia trachomatisvariants
dc.year.issued2020

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
s12879-020-05148-7.pdf
Size:
318.22 KB
Format:
Adobe Portable Document Format
Description:
Publisher's version