Evaluation of image quality with four positron emitters and three preclinical PET/CT systems

dc.contributor.authorTeuho J
dc.contributor.authorRiehakainen L
dc.contributor.authorHonkaniemi A
dc.contributor.authorMoisio O
dc.contributor.authorHan CL
dc.contributor.authorTirri M
dc.contributor.authorLiu SH
dc.contributor.authorGrönroos TJ
dc.contributor.authorLiu J
dc.contributor.authorWan L
dc.contributor.authorLiang X
dc.contributor.authorLing YQ
dc.contributor.authorHua YX
dc.contributor.authorRoivainen A
dc.contributor.authorKnuuti J
dc.contributor.authorXie QG
dc.contributor.authorTeräs M
dc.contributor.authorD'Ascenzo N
dc.contributor.authorKlen R
dc.contributor.author
dc.contributor.organizationfi=MediCity|en=MediCity|
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=kliininen fysiologia ja isotooppilääketiede|en=Clinical Physiology and Isotope Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.75985703497
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.converis.publication-id51256727
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/51256727
dc.date.accessioned2022-10-28T12:20:36Z
dc.date.available2022-10-28T12:20:36Z
dc.description.abstractBackground We investigated the image quality of C-11, Ga-68, F-18 and Zr-89, which have different positron fractions, physical half-lifes and positron ranges. Three small animal positron emission tomography/computed tomography (PET/CT) systems were used in the evaluation, including the Siemens Inveon, RAYCAN X5 and Molecubes beta-cube. The evaluation was performed on a single scanner level using the national electrical manufacturers association (NEMA) image quality phantom and analysis protocol. Acquisitions were performed with the standard NEMA protocol for F-18 and using a radionuclide-specific acquisition time for C-11, Ga-68 and Zr-89. Images were assessed using percent recovery coefficient (%RC), percentage standard deviation (%STD), image uniformity (%SD), spill-over ratio (SOR) and evaluation of image quantification. Results Ga-68 had the lowest %RC (< 62%) across all systems. F-18 had the highest maximum %RC (> 85%) and lowest %STD for the 5 mm rod across all systems. For C-11 and Zr-89, the maximum %RC was close (> 76%) to the %RC with F-18. A larger SOR were measured in water with C-11 and Ga-68 compared to F-18 on all systems. SOR in air reflected image reconstruction and data correction performance. Large variation in image quantification was observed, with maximal errors of 22.73% (Zr-89, Inveon), 17.54% (Zr-89, RAYCAN) and - 14.87% (Ga-68, Molecubes). Conclusions The systems performed most optimal in terms of NEMA image quality parameters when using F-18, where C-11 and Zr-89 performed slightly worse than F-18. The performance was least optimal when using Ga-68, due to large positron range. The large quantification differences prompt optimization not only by terms of image quality but also quantification. Further investigation should be performed to find an appropriate calibration and harmonization protocol and the evaluation should be conducted on a multi-scanner and multi-center level.
dc.identifier.jour-issn2191-219X
dc.identifier.olddbid175968
dc.identifier.oldhandle10024/159062
dc.identifier.urihttps://www.utupub.fi/handle/11111/30414
dc.identifier.urnURN:NBN:fi-fe2021042824148
dc.language.isoen
dc.okm.affiliatedauthorTeuho, Jarmo
dc.okm.affiliatedauthorHonkaniemi, Aake
dc.okm.affiliatedauthorMoisio, Olli
dc.okm.affiliatedauthorHan, Chunlei
dc.okm.affiliatedauthorTirri, Marko
dc.okm.affiliatedauthorGrönroos, Tove
dc.okm.affiliatedauthorDataimport, MediCity
dc.okm.affiliatedauthorRoivainen, Anne
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorTeräs, Mika
dc.okm.affiliatedauthorKlén, Riku
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline318 Medical biotechnologyen_GB
dc.okm.discipline318 Lääketieteen bioteknologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSPRINGER
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.articlenumberARTN 155
dc.relation.doi10.1186/s13550-020-00724-z
dc.relation.ispartofjournalEJNMMI Research
dc.relation.issue1
dc.relation.volume10
dc.source.identifierhttps://www.utupub.fi/handle/10024/159062
dc.titleEvaluation of image quality with four positron emitters and three preclinical PET/CT systems
dc.year.issued2020