Validation of Finnish Neecham Confusion Scale and Nursing Delirium Screening Scale using Confusion Assessment Method algorithm as a comparison scale

dc.contributor.authorPoikajärvi S
dc.contributor.authorSalanterä S
dc.contributor.authorKatajisto J
dc.contributor.authorJunttila K
dc.contributor.author
dc.contributor.organizationfi=hoitotieteen laitos|en=Department of Nursing Science|
dc.contributor.organizationfi=tilastotiede|en=Statistics|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.27201741504
dc.contributor.organization-code1.2.246.10.2458963.20.42133013740
dc.contributor.organization-code2607400
dc.converis.publication-id18273097
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/18273097
dc.date.accessioned2022-10-28T13:41:19Z
dc.date.available2022-10-28T13:41:19Z
dc.description.abstract<p>Background: Delirium is a common clinical problem with acute and fluctuating onset. Early notification of its symptoms can lead to earlier detection and management of this state. Valid and reliable instruments are required for successful nursing practice. The purpose of the study was to psychometrically test the Finnish versions of the Neecham Confusion Scale (NEECHAM) and the Nursing Delirium Screening Scale (Nu-DESC) in surgical nursing care, utilizing the Confusion Assessment Method (CAM) algorithm as a comparison scale. Methods: This randomized, blinded, instrument testing study was conducted at one university hospital in one surgical unit. Study patients (n = 112) meeting the pre-set criteria were assessed by the principal investigator (PI) and a registered nurse (RN, n = 18). Internal consistency, inter-rater reliability, and concurrent validity of the scales were calculated and face validity and usability evaluated. Results: Internal consistency was from .76 to .86 for all three scales. Inter-rater reliability between PI and RNs was .87 with NEECHAM, .60 with CAM and .47 with Nu-DESC. Concurrent validity was .56 and .59 between CAM and NEECHAM, and .68 and .72 between NEECHAM and Nu-DESC. In the PI group, the correlation between CAM and Nu-DESC was .91, in the RN’s group .42. Nu-DESC was evaluated as the most usable scale. Conclusion: The findings strengthen the earlier research on the scales and indicate that the Finnish NEECHAM and Nu-DESC correlates with CAM algorithm and with each other. They seem to be clinically viable in assessing patients’ delirium in surgical wards but more validity testing is needed. Keywords: Confusion, Confusion Assessment Method, Delirium, Instrument testing, Neecham Confusion Scale, Nursing Delirium Screening Scale<br /></p>
dc.identifier.jour-issn1472-6955
dc.identifier.olddbid183632
dc.identifier.oldhandle10024/166726
dc.identifier.urihttps://www.utupub.fi/handle/11111/33541
dc.identifier.urnURN:NBN:fi-fe2021042716253
dc.language.isoen
dc.okm.affiliatedauthorPoikajärvi, Satu
dc.okm.affiliatedauthorSalanterä, Sanna
dc.okm.affiliatedauthorJunttila, Anna-Kristiina
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.affiliatedauthorKatajisto, Jouko
dc.okm.discipline316 Nursingen_GB
dc.okm.discipline316 Hoitotiedefi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBIO Med Central
dc.relation.articlenumber7
dc.relation.doi10.1186/s12912-016-0199-6
dc.relation.ispartofjournalBMC Nursing
dc.relation.volume16
dc.source.identifierhttps://www.utupub.fi/handle/10024/166726
dc.titleValidation of Finnish Neecham Confusion Scale and Nursing Delirium Screening Scale using Confusion Assessment Method algorithm as a comparison scale
dc.year.issued2017

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
art%3A10.1186%2Fs12912-016-0199-6.pdf
Size:
622.56 KB
Format:
Adobe Portable Document Format
Description:
Publisher's version