Radiographic geometry and clinical glenohumeral range of motion after reverse shoulder athroplasty, a retrospective cohort study

dc.contributor.authorLehtimäki Kaisa
dc.contributor.authorHarjula Jenni
dc.contributor.authorUurinmäki Joonas
dc.contributor.authorKukkonen Juha
dc.contributor.authorLöyttyniemi Eliisa
dc.contributor.authorMokka Jari
dc.contributor.authorTiusanen Hannu
dc.contributor.authorÄärimaa Ville
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.converis.publication-id59083157
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/59083157
dc.date.accessioned2022-10-27T11:54:24Z
dc.date.available2022-10-27T11:54:24Z
dc.description.abstract<p>Background</p><p>The range of motion (ROM) in reverse shoulder arthroplasty (RSA), is mechanically limited by the surrounding bony obstacles especially in abduction and rotation planes. However, the clinical effect of implant positioning, prosthesis design, and individual differences in bone morphology, on ROM is obscure. The aim of this study was to investigate the correlation between radiographic geometry and clinical glenohumeral (GH) ROM after RSA.<br /></p><p>Methods</p><p>RSA patients operated at Turku University Hospital during 2007–2013 were called for radiological and clinical follow-up. Pre- and postoperative true anteroposterior radiographs were obtained and the positioning of the center of rotation (COR) in relation to the surrounding bony structures was measured. Active and passive shoulder and GH abduction, flexion, internal and external rotation ROM were measured with goniometer. The Constant score (CS) and pain visual analogue scale (VAS) were recorded. The correlation between the radiographically measured parameters and the active and passive ROM and clinical outcome was statistically analyzed.<br /></p><p>Results</p><p>91 shoulders were available for analyses with a mean follow-up of 38.7 months ± SD 20 (range 12–83) months. 77% of the patients were female, the mean age was 73 (SD 9) years. The mean angle between the line of supraspinatus fossa, and the line between COR and lateral edge of the acromion (α-angle) was 127° (SD 14) and the mean angle between the lines from lateral edge of the acromion to COR, and from there to the superior edge of the greater tubercle (β-angle) was 54° (SD 11). The mean active shoulder flexion at follow-up was 118° (SD 26), abduction 104° (SD 32), external rotation 41° (SD 22), internal rotation 77° (SD 21). The mean passive GH flexion was 80° (SD 19), abduction 67° (SD 15), external rotation 31° (SD 16) and internal rotation 34° (SD 14). The mean Constant score at follow-up was 53 (SD 18) and pain VAS 2 (SD 3). The positioning of the radiographically measured COR did not statistically significantly correlate with the ROM or clinical outcome scores.<br /></p><p>Conclusions</p><p>Postoperative radiographically measured two-dimensional geometry and positioning of the COR does not significantly correlate with the glenohumeral range of motion or clinical results after RSA.<br /></p>
dc.format.pagerange287
dc.identifier.eissn0972-978X
dc.identifier.jour-issn2589-9082
dc.identifier.olddbid172717
dc.identifier.oldhandle10024/155811
dc.identifier.urihttps://www.utupub.fi/handle/11111/54578
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0972978X21001264?via=ihub
dc.identifier.urnURN:NBN:fi-fe2021093047977
dc.language.isoen
dc.okm.affiliatedauthorLehtimäki, Kaisa
dc.okm.affiliatedauthorKukkonen, Juha
dc.okm.affiliatedauthorLöyttyniemi, Eliisa
dc.okm.affiliatedauthorTiusanen, Hannu
dc.okm.affiliatedauthorÄärimaa, Ville
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherReed Elsevier India Pvt. Ltd.
dc.publisher.countryIndiaen_GB
dc.publisher.countryIntiafi_FI
dc.publisher.country-codeIN
dc.relation.doi10.1016/j.jor.2021.05.018
dc.relation.ispartofjournalJournal of Orthopaedics
dc.relation.volume25
dc.source.identifierhttps://www.utupub.fi/handle/10024/155811
dc.titleRadiographic geometry and clinical glenohumeral range of motion after reverse shoulder athroplasty, a retrospective cohort study
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S0972978X21001264-main.pdf
Size:
1.35 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF