Dynamic Modelling and Simulation of a Single-Effect Absorption Chiller

dc.contributor.authorSaha, Nilotpaul
dc.contributor.departmentfi=Kone- ja materiaalitekniikan laitos|en=Department of Mechanical and Materials Engineering|
dc.contributor.facultyfi=Teknillinen tiedekunta|en=Faculty of Technology|
dc.contributor.studysubjectfi=Konetekniikka|en=Mechanical Engineering|
dc.date.accessioned2026-07-04T19:31:21Z
dc.date.issued2026-06-27
dc.description.abstractAbsorption refrigeration systems driven by low-grade thermal energy offer a sustainable alternative to conventional vapour compression chillers, replacing the mechanical compressor with a thermochemical cycle driven primarily by waste heat (Florides et al., 2003). The lithium bromide– water (LiBr/H₂O) working pair is well-suited for single-effect cooling, operating effectively with heat source temperatures of 75–120 °C and making it directly compatible with marine waste heat applications (Salmi et al., 2017a). Because absorption machines possess large thermal inertia, dynamic simulation is essential for predicting transient responses, evaluating part-load performance, and designing effective control strategies (Kohlenbach and Ziegler, 2008a). This thesis presents the development and successful implementation of a dynamic, lumped-parameter simulation model for a single-effect LiBr/H₂O absorption chiller in MATLAB/Simulink. Following the state-space framework of Wen et al., (2019), the model is governed by coupled first-order ordinary differential equations derived from conservation of mass, species, and energy. Thermodynamic properties are computed using the correlations of Pátek and Klomfar, (2006) and Florides et al., (2003), with specific heat capacity derived as the analytical temperature derivative of the enthalpy correlation to ensure thermodynamic consistency. To overcome the numerical instability of the baseline model, two architectural modifications were introduced: a dynamic condenser pressure scaling mechanism proportionally linked to instantaneous liquid refrigerant mass, and an 8-stage spatially discretised counter-flow solution heat exchanger with finite thermal mass at each node. These modifications yield a robust, fully functional integrated model. Simulation results across three parametric scenarios demonstrate stable transient convergence, with a baseline COP of 0.718 (driving heat input is waste heat) establishing a computationally efficient tool for predicting absorption chiller behaviour under varying operational conditions.
dc.format.extent112
dc.identifier.urihttps://www.utupub.fi/handle/11111/62711
dc.identifier.urnURN:NBN:fi-fe20260703109250
dc.language.isoeng
dc.rightsfi=Julkaisu on tekijänoikeussäännösten alainen. Teosta voi lukea ja tulostaa henkilökohtaista käyttöä varten. Käyttö kaupallisiin tarkoituksiin on kielletty.|en=This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.|
dc.rights.accessrightsavoin
dc.subjectAbsorption chiller
dc.subjectdynamic modelling
dc.subjectSimulink
dc.subjectstate-space model
dc.subjecttransient simulation
dc.subjectthermodynamic instability
dc.subjectwaste heat recovery
dc.titleDynamic Modelling and Simulation of a Single-Effect Absorption Chiller
dc.type.ontasotfi=Diplomityö|en=Master's thesis|