Continuous Blood Pressure Monitoring Using Nonpulsatile Photoplethysmographic Components for Low-Frequency Vascular Unloading

dc.contributor.authorPanula Tuukka
dc.contributor.authorSirkiä Jukka-Pekka
dc.contributor.authorKaisti Matti
dc.contributor.organizationfi=terveysteknologia|en=Health Technology|
dc.contributor.organization-code1.2.246.10.2458963.20.28696315432
dc.converis.publication-id179486709
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/179486709
dc.date.accessioned2025-08-28T01:43:19Z
dc.date.available2025-08-28T01:43:19Z
dc.description.abstract<p>Continuous blood pressure (BP) monitoring gives a better understanding of a person’s cardiovascular health status than single BP measurements. The existing measurement techniques are often highly complex and expensive or suffer from inaccuracies. We propose a simple, yet effective technique for continuous BP monitoring. Our method is based on the finding that the nonpulsatile (dc) component of the photoplethysmograph (PPG) correlates with BP. By keeping the infrared (IR) PPG dc component constant by altering the applied external pressure using a feedback mechanism, the BP can be measured continuously. This way the pressure reading from the pressure sensor follows the mean intraarterial BP. We call this low-frequency vascular unloading. We propose a method for assessing the measurement error introduced by changes in vasomotor tone. Green PPG was used for the vasomotor compensation method. We packaged the technology into a wearable finger-worn device similar to a pulse oximeter probe. We measured over 90 min of continuous BP data from a total of seven subjects. The subjects were asked to perform different BP-altering maneuvers during the measurement. The ability to track BP changes was verified by continuous mean arterial pressure (MAP) readings measured with the reference device (CNSystems CNAP 500) and our device, resulting in the correlation of $r=0.894$ and [ $(\text {mean} \pm \text {SD})$ mmHg] of $(0.3 \pm 4.3)$ mmHg for MAP. Without vasomotor tone compensation (VMC), the results were slightly less accurate: $r=0.83$ , $(-1.4 \pm 5.1)$ mmHg. The proposed technology performed well compared to the traditional vascular unloading technique (VUT) while requiring significantly less complex control logic and no fast-switching pneumatics. The proposed technique is a simple, yet effective, low-cost solution and it can be constructed from off-the-shelf components and miniaturized into a wearable form factor. The technique has potential in the field of health wearables and remote continuous BP monitoring for personalized health applications.</p>
dc.identifier.eissn1557-9662
dc.identifier.jour-issn0018-9456
dc.identifier.olddbid207955
dc.identifier.oldhandle10024/190982
dc.identifier.urihttps://www.utupub.fi/handle/11111/57310
dc.identifier.urlhttps://ieeexplore.ieee.org/document/10102562/
dc.identifier.urnURN:NBN:fi-fe2023051644552
dc.language.isoen
dc.okm.affiliatedauthorPanula, Tuukka
dc.okm.affiliatedauthorSirkiä, Jukka-Pekka
dc.okm.affiliatedauthorKaisti, Matti
dc.okm.discipline217 Medical engineeringen_GB
dc.okm.discipline217 Lääketieteen tekniikkafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherInstitute of Electrical and Electronics Engineers
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.articlenumber4004910
dc.relation.doi10.1109/TIM.2023.3267378
dc.relation.ispartofjournalIEEE Transactions on Instrumentation and Measurement
dc.relation.volume72
dc.source.identifierhttps://www.utupub.fi/handle/10024/190982
dc.titleContinuous Blood Pressure Monitoring Using Nonpulsatile Photoplethysmographic Components for Low-Frequency Vascular Unloading
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Continuous_Blood_Pressure_Monitoring_Using_Nonpulsatile_Photoplethysmographic_Components_for_Low-Frequency_Vascular_Unloading.pdf
Size:
18.98 MB
Format:
Adobe Portable Document Format