Validation of HDR brachytherapy doses in the treatment of keloid scars using the egs_brachy Monte Carlo application

dc.contributor.authorSaikkonen Aleksi
dc.contributor.authorOjala Jarkko
dc.contributor.authorSipilä Petri
dc.contributor.authorBoman Eeva
dc.contributor.authorKeyriläinen Jani
dc.contributor.organizationfi=fysiikan ja tähtitieteen laitos|en=Department of Physics and Astronomy|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.55477946762
dc.contributor.organization-code2606700
dc.converis.publication-id179518819
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/179518819
dc.date.accessioned2025-08-27T22:39:18Z
dc.date.available2025-08-27T22:39:18Z
dc.description.abstract<p><strong>Objective</strong> <br></p><p>Radiotherapy is a well-known alternative in the treatment of keloid scars to reduce the recurrence of scars. The purpose of this study was to investigate the feasibility and accuracy of dose delivered from a high-dose-rate (HDR) afterloaders in keloid scar brachytherapy using Monte Carlo (MC) simulations and measurements. <br></p><p><strong>Approach</strong><br></p><p><strong></strong>Treatment doses and central axis dose profiles were measured using radiophotoluminescence dosimeters and radiochromic films, respectively, with two HDR afterloaders, both using an Ir-192 source, in a phantom made of solid water and polycarbonate sheets. The nominal treatment dose calculated by the AAPM Task Group No. 43 (TG-43) dose model was set to 8.5 Gy at a distance of 0.5 cm laterally from the middle of the source line located in a plastic applicator simulating a 15 cm long surgically removed scar treatment with 30 equally spaced (0.5 cm) source positions. The dose profiles were measured at three different distances from the applicator and the absolute doses at four points at different distances. MC simulations were performed using the egs_brachy, which is based on EGSnrc code system. <br></p><p><strong>Main results</strong><br></p><p><strong></strong>The measured and simulated dose profiles match well, especially at 10.0 mm (difference <1%) and 15.0 mm depths (difference <4%), and with a small dose difference at 5.0 mm depth (difference <4%). Point dose measurements agreed well in the dose maximum area (difference <7%) with the simulated dose profiles, although the largest difference near the edge of the profile was <30%. The dose differences between the TG-43 dose model and the MC simulation were small (differences <4%). <br></p><p><strong>Significance</strong><br></p><p><strong></strong>Simulated and measured dose levels at a depth of 0.5 cm showed that the nominal treatment dose can be achieved with the utilized setup. The measurement results of the absolute dose agree well with the corresponding simulation results.<br></p>
dc.identifier.eissn1361-6560
dc.identifier.jour-issn0031-9155
dc.identifier.olddbid202557
dc.identifier.oldhandle10024/185584
dc.identifier.urihttps://www.utupub.fi/handle/11111/47619
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/1361-6560/acc30a
dc.identifier.urnURN:NBN:fi-fe2023052045604
dc.language.isoen
dc.okm.affiliatedauthorSaikkonen, Aleksi
dc.okm.affiliatedauthorKeyriläinen, Jani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline114 Physical sciencesen_GB
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline114 Fysiikkafi_FI
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherIOP Publishing Ltd
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumber084003
dc.relation.doi10.1088/1361-6560/acc30a
dc.relation.ispartofjournalPhysics in Medicine and Biology
dc.relation.issue8
dc.relation.volume68
dc.source.identifierhttps://www.utupub.fi/handle/10024/185584
dc.titleValidation of HDR brachytherapy doses in the treatment of keloid scars using the egs_brachy Monte Carlo application
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Saikkonen_2023_Phys._Med._Biol._68_084003.pdf
Size:
988.85 KB
Format: