Fracture behavior of discontinuous fiber-reinforced composite inlay-retained fixed partial denture before and after fatigue aging

dc.contributor.authorLassila Lippo
dc.contributor.authorMangoush Enas
dc.contributor.authorVallittu Pekka
dc.contributor.authorGaroushi Sufyan
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.converis.publication-id175768081
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/175768081
dc.date.accessioned2022-10-27T11:44:32Z
dc.date.available2022-10-27T11:44:32Z
dc.description.abstract<p><strong>Purpose: </strong>To evaluate the fracture behavior of inlay-retained fixed partial dentures (IRFPDs) made of experimental short fiber-reinforced composite (SFRC) computer-aided design/computer-aided manufacturing (CAD/CAM) block before and after cyclic fatigue aging.</p><p><strong>Methods: </strong>Five groups (n=20/group) of three-unit posterior IRFPDs were fabricated. The first and second groups were CAD/CAM fabricated from experimental SFRC blocks or lithium-disilicate (IPS e.max CAD, IVOCLAR) materials, the third group comprised a three-dimensional-printed composite (Temp PRINT, GC), and the fourth and fifth groups comprised conventional laboratory flowable composite (Gradia Plus, GC) and commercial flowable SFRC (everX Flow, GC), respectively. All IRFPDs were luted into a metal jig with adhesive dual-cure resin cement (RelyX Ultimate, 3M ESPE). Half the IRFPDs per group (n=10) were subjected to fatigue aging for 10,000 cycles. The remaining half were statically loaded until fracture without fatigue aging. The load was applied vertically between triangular ridges of the buccal and lingual cusps. The fracture mode was visually examined using optical and scanning electron microscopy (SEM). Data were statistically analyzed using a two-way analysis of variance (ANOVA) followed by Tukey's HSD test.</p><p><strong>Results: </strong>ANOVA revealed that IRFPDs made of experimental SFRC CAD/CAM had the highest (p<0.05) load-bearing capacity before (2624±463 N) and after (2775±297 N) aging among all groups. Cyclic fatigue aging decreased the load-bearing capacity (<em>p</em>>0.05) of all tested prostheses, except for the experimental SFRC CAD/CAM and conventional laboratory composite IRFPDs (<em>p</em>>0.05). SEM images showed the ability of discontinuous short fibers in the experimental SFRC CAD/CAM composite to redirect and hinder crack propagation.</p><p><strong>Conclusion: </strong>CAD/CAM-fabricated IRFPDs made of experimental SFRC blocks showed promising performance in clinical testing in terms of fracture behavior.</p>
dc.identifier.eissn1883-9207
dc.identifier.jour-issn1883-1958
dc.identifier.olddbid171818
dc.identifier.oldhandle10024/154912
dc.identifier.urihttps://www.utupub.fi/handle/11111/45022
dc.identifier.urnURN:NBN:fi-fe2022081153642
dc.language.isoen
dc.okm.affiliatedauthorLassila, Lippo
dc.okm.affiliatedauthorMangoush, Enas
dc.okm.affiliatedauthorVallittu, Pekka
dc.okm.affiliatedauthorGaroushi, Sufyan
dc.okm.discipline313 Dentistryen_GB
dc.okm.discipline313 Hammaslääketieteetfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier
dc.publisher.countryJapanen_GB
dc.publisher.countryJapanifi_FI
dc.publisher.country-codeJP
dc.publisher.placeJapan
dc.relation.doi10.2186/jpr.JPR_D_22_00050
dc.relation.ispartofjournalJournal of Prosthodontic Research
dc.source.identifierhttps://www.utupub.fi/handle/10024/154912
dc.titleFracture behavior of discontinuous fiber-reinforced composite inlay-retained fixed partial denture before and after fatigue aging
dc.year.issued2022

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
advpub_JPR_D_22_00050.pdf
Size:
4.41 MB
Format:
Adobe Portable Document Format