Repeated cobalt and chromium ion measurements in patients with bilateral large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement

dc.contributor.authorSakari Pietiläinen
dc.contributor.authorHeikki Mäntymäki
dc.contributor.authorTero Vahlberg
dc.contributor.authorAleksi Reito
dc.contributor.authorAntti Eskelinen
dc.contributor.authorPetteri Lankinen
dc.contributor.authorKeijo Mäkelä
dc.contributor.organizationfi=biostatistiikka|en=Biostatistics|
dc.contributor.organizationfi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.89365200099
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.contributor.organization-code2607310
dc.converis.publication-id47400621
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/47400621
dc.date.accessioned2025-08-27T22:53:26Z
dc.date.available2025-08-27T22:53:26Z
dc.description.abstract<p>Background and purpose: Whole-blood (WB) chromium (Cr) and cobalt (Co) measurements are vital in the follow-up of metal-on-metal total hip replacement (MoM THR) patients. We examined whether there is a substantial change in repeated WB, Co, and Cr levels in patients with bilateral ReCap-M2A-Magnum THR. We also specified the number of patients exceeding the safe upper limit (SUL) of WB Co and Cr in the repeated measurement.<br /><br />Patients and methods: We identified 141 patients with bilateral ReCap-M2A-Magnum THR operated in our institution. 61 patients had repeated WB metal ion measurements with bilateral MoM implants still in situ in the second measurement. The mean time elapsing from the first measurement (initial measurement) to the second (control measurement) was 1.9 years (SD = 0.6, range 0.2–3.5). We used earlier established SUL levels for bilateral implants by Van Der Straeten et al. (2013).<br /><br />Results: The median (range) Co and Cr values decreased in the repeated measurement from 2.7 (0.6–25) to 2.1 (0.5–21) and 2.6 (0.8–14) to 2.1 (0.5–18) respectively. In 13% of the patients Co levels exceeded the SUL in the initial measurement and the proportion remained constant, at 13%, in the repeated measurement. In 5% of the patients, Cr levels were above SUL in the initial measurement and an equal 5% in the control measurement.<br /><br />Interpretation: Repeated WB metal ion levels did not increase in patients with bilateral ReCap-M2A-Magnum THR with a mean 1.9-year measurement interval. Long-term development of WB metal ion levels is still unclear in these patients.<br /></p>
dc.format.pagerange378
dc.format.pagerange382
dc.identifier.eissn1745-3674
dc.identifier.jour-issn1745-3674
dc.identifier.olddbid202999
dc.identifier.oldhandle10024/186026
dc.identifier.urihttps://www.utupub.fi/handle/11111/48793
dc.identifier.urnURN:NBN:fi-fe2021042821531
dc.language.isoen
dc.okm.affiliatedauthorPietiläinen, Sakari
dc.okm.affiliatedauthorMäntymäki, Heikki
dc.okm.affiliatedauthorVahlberg, Tero
dc.okm.affiliatedauthorMäkelä, Keijo
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherTaylor and Francis Ltd
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1080/17453674.2020.1751940
dc.relation.ispartofjournalActa Orthopaedica
dc.relation.issue4
dc.relation.volume91
dc.source.identifierhttps://www.utupub.fi/handle/10024/186026
dc.titleRepeated cobalt and chromium ion measurements in patients with bilateral large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement
dc.year.issued2020

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Pietilainen_et_al_AO_2020.pdf
Size:
931.35 KB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF