The ceramic coated implant (CCI). Evolution total ankle replacements: a retrospective analysis of 40 ankles with 8 years follow-up

dc.contributor.authorKormi Sami
dc.contributor.authorKoivu Helka
dc.contributor.authorKohonen Ia
dc.contributor.authorMäkelä Keijo
dc.contributor.authorTiusanen Hannu
dc.contributor.authorSaltychev Mikhail
dc.contributor.organizationfi=fysiatria|en=Physical and Rehabilitation Medicine|
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=ortopedia ja traumatologia|en=Orthopaedics and Traumatology|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.17712075286
dc.contributor.organization-code1.2.246.10.2458963.20.69079168212
dc.contributor.organization-code1.2.246.10.2458963.20.90281651480
dc.converis.publication-id181932361
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/181932361
dc.date.accessioned2025-08-27T21:32:13Z
dc.date.available2025-08-27T21:32:13Z
dc.description.abstractDiminutive data is available on the outcome of several previously used total ankle replacement implants. The purpose of this study was to investigate the medium-term functional and radiological outcome and implant survival of the CCI Evolution implant. Consecutive series of 40 ankles operated in our hospital with primary TAR using the CCI Evolution implant in 2010-2013 were available for follow-up. The prospective clinical and radiographic data including the Kofoed score, subjective satisfaction and standard radiographs were collected preoperatively and at fixed time-points postoperatively. A CT was obtained in cases where osteolysis or loosening were suspected. The improvement of the Kofoed score and subjective satisfaction were statistically significant (p<0.0001). The implant survival was 97% (95% confidence interval (CI) 81%-100 %) at 5 years, and 81 % (95% confidence interval (CI) 60 %-92%) at 8 years. There were altogether 25 (64%) complications. Overall revision rate was 28% and failure rate 13%. The CCI implant outcome was not acceptable. The malposition of prosthetic components, subsidence, and peri-implant osteolysis were recorded often. Although the patient reported outcome measures improved, mostly due to positive changes in pain severity, overall revision and failure rates were high and comparable with previous findings of the CCI implant.
dc.format.pagerange515
dc.format.pagerange524
dc.identifier.jour-issn0001-6462
dc.identifier.olddbid200575
dc.identifier.oldhandle10024/183602
dc.identifier.urihttps://www.utupub.fi/handle/11111/45660
dc.identifier.urlhttp://www.actaorthopaedica.be/archive/volume-89/issue-3/original-studies/the-ceramic-coated-implant-cci-evolution-total-ankle-replacements-a-retrospective-analysis-of-40-ank/
dc.identifier.urnURN:NBN:fi-fe2025082785054
dc.language.isoen
dc.okm.affiliatedauthorKormi, Sami
dc.okm.affiliatedauthorKoivu, Helka
dc.okm.affiliatedauthorKohonen, Ia
dc.okm.affiliatedauthorMäkelä, Keijo
dc.okm.affiliatedauthorTiusanen, Hannu
dc.okm.affiliatedauthorSaltychev, Mikhail
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisher.countryBelgiumen_GB
dc.publisher.countryBelgiafi_FI
dc.publisher.country-codeBE
dc.relation.doi10.52628/89.3.11585
dc.relation.ispartofjournalActa orthopaedica Belgica (bilingual edition)
dc.relation.issue3
dc.relation.volume89
dc.source.identifierhttps://www.utupub.fi/handle/10024/183602
dc.titleThe ceramic coated implant (CCI). Evolution total ankle replacements: a retrospective analysis of 40 ankles with 8 years follow-up
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Kormi et al.2023_ The ceramic coated implant_parallel published.pdf
Size:
563.29 KB
Format:
Adobe Portable Document Format