Inter-Laboratory Study on Measuring the Surface Charge of Electrically Polarized Hydroxyapatite

dc.contributor.authorUbele-Kalnina Darta
dc.contributor.authorNakamura Miho
dc.contributor.authorGross Karlis Agris
dc.contributor.organizationfi=MediCity|en=MediCity|
dc.contributor.organization-code1.2.246.10.2458963.20.83772236069
dc.converis.publication-id179123336
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/179123336
dc.date.accessioned2025-08-27T22:25:51Z
dc.date.available2025-08-27T22:25:51Z
dc.description.abstract<p>Surface charges on implants improve integration into bone and so require a clear protocol for achieving a surface charge and comparable results from different laboratories. This study sintered hydroxyapatite (HAp) at one laboratory to remove the influence of the microstructure on surface charge and then polarized/depolarized the pellets at two different laboratories (in Tokyo and Riga). Surface charges on HAp pellets induced by electric polarization at 400 °C in a 5 kV/cm DC electric field were measured by the thermally stimulated depolarization current (TSDC) method as 6–9 µC/cm2. The surface charge results were comparable between laboratories and also agreed with previously documented values. Recommendations describe conditions for polarization and depolarization to generate a surface charge and repeatedly achieve a comparable outcome. A visual display of the polarization mechanisms and the contribution to surface charge point to further aspects that need further development.<br></p>
dc.identifier.eissn2079-4983
dc.identifier.jour-issn2079-4983
dc.identifier.olddbid202153
dc.identifier.oldhandle10024/185180
dc.identifier.urihttps://www.utupub.fi/handle/11111/46186
dc.identifier.urlhttps://doi.org/10.3390/jfb14020100
dc.identifier.urnURN:NBN:fi-fe2023040535088
dc.language.isoen
dc.okm.affiliatedauthorNakamura, Miho
dc.okm.discipline3111 Biomedicineen_GB
dc.okm.discipline3111 Biolääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherMDPI
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.articlenumber100
dc.relation.doi10.3390/jfb14020100
dc.relation.ispartofjournalJournal of Functional Biomaterials
dc.relation.issue2
dc.relation.volume14
dc.source.identifierhttps://www.utupub.fi/handle/10024/185180
dc.titleInter-Laboratory Study on Measuring the Surface Charge of Electrically Polarized Hydroxyapatite
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
jfb-14-00100-v2.pdf
Size:
1.58 MB
Format:
Adobe Portable Document Format