Myocardial perfusion quantification with Rb-82 PET: good interobserver agreement of Carimas software on global, regional, and segmental levels

dc.contributor.authorNesterov Sergey V
dc.contributor.authorDeshayes Emmanuel
dc.contributor.authorJuarez-Orozco Luis Eduardo
dc.contributor.authordeKemp Robert A
dc.contributor.authorSciagrà Roberto
dc.contributor.authorMalaspina Simona
dc.contributor.authorSettimo Leonardo
dc.contributor.authorHan Chunlei
dc.contributor.authorRyzhkova Darja V
dc.contributor.authorKostina Irina S
dc.contributor.authorGwet Kilem L
dc.contributor.authorPrior John O
dc.contributor.authorKnuuti Juhani M
dc.contributor.organizationfi=InFLAMES Lippulaiva|en=InFLAMES Flagship|
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=kliininen fysiologia ja isotooppilääketiede|en=Clinical Physiology and Isotope Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.68445910604
dc.contributor.organization-code2607322
dc.contributor.organization-code2609810
dc.converis.publication-id174852692
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/174852692
dc.date.accessioned2022-10-27T11:55:15Z
dc.date.available2022-10-27T11:55:15Z
dc.description.abstract<p>Purpose<br>To estimate the interobserver agreement of the Carimas software package (SP) on global, regional, and segmental levels for the most widely used myocardial perfusion PET tracer-Rb-82.</p><p>Materials and methods<br>Rest and stress Rb-82 PET scans of 48 patients with suspected or known coronary artery disease (CAD) were analyzed in four centers using the Carimas SP. We considered values to agree if they simultaneously had an intraclass correlation coefficient (ICC) > 0.75 and a difference < 20% of the median across all observers.<br></p><p>Results<br>The median values on the segmental level were 1.08 mL/min/g for rest myocardial blood flow (MBF), 2.24 mL/min/g for stress MBF, and 2.17 for myocardial flow reserve (MFR). For the rest MBF and MFR, all the values at all the levels fulfilled were in excellent agreement. For stress MBF, at the global and regional levels, all the 24 comparisons showed excellent agreement. Only 1 out of 102 segmental comparisons (seg. 14) was over the adequate agreement limit-23.5% of the median value (ICC = 0.95).<br></p><p>Conclusion<br>Interobserver agreement for Rb-82 PET myocardial perfusion quantification analyzed with Carimas is good at any LV segmentation level-global, regional, and segmental. It is good for all the estimates-rest MBF, stress MBF, and MFR.</p>
dc.identifier.eissn1864-6433
dc.identifier.jour-issn0914-7187
dc.identifier.olddbid172821
dc.identifier.oldhandle10024/155915
dc.identifier.urihttps://www.utupub.fi/handle/11111/30647
dc.identifier.urlhttps://link.springer.com/article/10.1007/s12149-022-01729-5
dc.identifier.urnURN:NBN:fi-fe2022081153748
dc.language.isoen
dc.okm.affiliatedauthorNesterov, Sergey
dc.okm.affiliatedauthorJuarez Orozco, Luis
dc.okm.affiliatedauthorMalaspina, Simona
dc.okm.affiliatedauthorHan, Chunlei
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSpringer
dc.publisher.countryJapanen_GB
dc.publisher.countryJapanifi_FI
dc.publisher.country-codeJP
dc.relation.doi10.1007/s12149-022-01729-5
dc.relation.ispartofjournalAnnals of Nuclear Medicine
dc.source.identifierhttps://www.utupub.fi/handle/10024/155915
dc.titleMyocardial perfusion quantification with Rb-82 PET: good interobserver agreement of Carimas software on global, regional, and segmental levels
dc.year.issued2022

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
NesterovEtAl2022MyocardialPerfusionQuantification.pdf
Size:
1013.33 KB
Format:
Adobe Portable Document Format