Variability of radiation doses of cardiac diagnostic imaging tests: the RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study)

dc.contributor.authorClara Carpeggiani
dc.contributor.authorEugenio Picano
dc.contributor.authorMarco Brambilla
dc.contributor.authorClaudio Michelassi
dc.contributor.authorJuhani Knuuti
dc.contributor.authorPhilipp Kauffman
dc.contributor.authorS. Richard Underwood
dc.contributor.authorDanilo Neglia and for the EVINCI Study Investigators
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.converis.publication-id19203839
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/19203839
dc.date.accessioned2022-10-27T11:58:36Z
dc.date.available2022-10-27T11:58:36Z
dc.description.abstractBackground: Patients with coronary artery disease can accumulate significant radiation dose through repeated exposures to coronary computed tomographic angiography, myocardial perfusion imaging with single photon emission computed tomography or positron emission tomography, and to invasive coronary angiography. Aim of the study was to audit radiation doses of coronary computed tomographic angiography, single photon emission computed tomography, positron emission tomography and invasive coronary angiography in patients enrolled in the prospective, randomized, multi-centre European study-EVINCI (Evaluation of Integrated Cardiac Imaging for the Detection and Characterization of Ischemic Heart Disease).Methods: We reviewed 1070 tests (476 coronary computed tomographic angiographies, 85 positron emission tomographies, 310 single photon emission computed tomographies, 199 invasive coronary angiographies) performed in 476 patients (mean age 60 +/- 9 years, 60% males) enrolled in 12 centers of the EVINCI. The effective doses were calculated in milli-Sievert (mSv) as median, interquartile range (IQR) and coefficient of variation of the mean.Results: Coronary computed tomographic angiography (476 exams in 12 centers) median effective dose was 9. 6 mSv (IQR = 13.2 mSv); single photon emission computed tomography (310 exams in 9 centers) effective dose was 9.3 (IQR = 2.8); positron emission tomography (85 in 3 centers) effective dose 1.8 (IQR = 1.6) and invasive coronary angiography (199 in 9 centers) effective dose 7.4 (IQR = 7.3). Inter-institutional variability was highest for invasive coronary angiography (100%) and coronary computed tomographic angiography (54%) and lowest for single photon emission computed tomography (20%). Intra-institutional variability was highest for invasive coronary angiography (121%) and coronary computed tomographic angiography (115%) and lowest for single photon emission computed tomography (14%).Conclusion: Coronary computed tomographic angiography and invasive coronary angiography doses vary substantially between and within centers. The variability in nuclear medicine procedures is substantially lower. The findings highlight the need to audit doses, to track cumulative exposures and to standardize doses for imaging techniques.
dc.identifier.jour-issn1471-2261
dc.identifier.olddbid173241
dc.identifier.oldhandle10024/156335
dc.identifier.urihttps://www.utupub.fi/handle/11111/31244
dc.identifier.urlhttps://bmccardiovascdisord.biomedcentral.com/articles/10.1186/s12872-017-0474-9
dc.identifier.urnURN:NBN:fi-fe2021042716644
dc.language.isoen
dc.okm.affiliatedauthorKnuuti, Juhani
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBIOMED CENTRAL LTD
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumber63
dc.relation.doi10.1186/s12872-017-0474-9
dc.relation.ispartofjournalBMC Cardiovascular Disorders
dc.relation.volume17
dc.source.identifierhttps://www.utupub.fi/handle/10024/156335
dc.titleVariability of radiation doses of cardiac diagnostic imaging tests: the RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study)
dc.year.issued2017