Investigating the short- and long-term effects of antibacterial agents using a real-time assay based on bioluminescent E. coli-lux

dc.contributor.authorSuominen Eetu
dc.contributor.authorPutus Tuula
dc.contributor.authorAtosuo Janne
dc.contributor.organizationfi=biokemia|en=Biochemistry|
dc.contributor.organizationfi=työterveyshuolto|en=Occupational Health|
dc.contributor.organization-code1.2.246.10.2458963.20.49728377729
dc.contributor.organization-code1.2.246.10.2458963.20.76843819186
dc.contributor.organization-code2610101
dc.converis.publication-id48380928
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/48380928
dc.date.accessioned2022-10-28T13:29:12Z
dc.date.available2022-10-28T13:29:12Z
dc.description.abstract<p>We have previously established that the <em>E. coli</em>-lux assessment is a convenient tool for rapid measurements of the kinetical features of short-term toxicity caused by various factors. In this study, kinetic measurements of seven specifically acting model antibacterials (i.e., polymyxin B, chloramphenicol, nalidixic acid, kanamycin, deoxynivalenol, erythromycin and tetracycline) and two metals (AgNO3 and CdCl2) against <em>E. coli</em>-lux through a bioluminescence- and optical density-based real-time assay that combined short- and long-term toxicity assessments were performed. Bacteria were exposed to antibacterials and the effects were reported as the half-maximum effective concentration (EC50) after 30 min and 10 h. Regarding the 10-hour endpoints, all reference compounds, except deoxynivalenol, showed dose-response inhibition in the studied concentration range. The analysis of chloramphenicol, kanamycin, erythromycin, tetracycline and nalidixic acid clearly revealed the limitations of short-term inhibition tests. No significant differences were observed between the results obtained from luminescence inhibition and growth inhibition assays. The kinetical data from measurements provide differentiation between bacteriostatic and bactericidal mechanisms of various types of antibacterial agents. The combined assessment of short- and long-term effects reduces the risk of the underestimation of toxicity due to an inaccurate endpoint selection. The cost-efficient and fully automated <em>E. coli</em>-lux assessment technique may offer possibilities for high-throughput screening procedures.<br /></p>
dc.identifier.eissn2405-8440
dc.identifier.jour-issn2405-8440
dc.identifier.olddbid182419
dc.identifier.oldhandle10024/165513
dc.identifier.urihttps://www.utupub.fi/handle/11111/39668
dc.identifier.urlhttps://www.cell.com/heliyon/fulltext/S2405-8440(20)31076-8
dc.identifier.urnURN:NBN:fi-fe2021042827284
dc.language.isoen
dc.okm.affiliatedauthorPutus, Tuula
dc.okm.affiliatedauthorAtosuo, Janne
dc.okm.affiliatedauthorSuominen, Eetu
dc.okm.discipline1182 Biochemistry, cell and molecular biologyen_GB
dc.okm.discipline1182 Biokemia, solu- ja molekyylibiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.articlenumberE04232
dc.relation.doi10.1016/j.heliyon.2020.e04232
dc.relation.ispartofjournalHeliyon
dc.relation.issue7
dc.relation.volume6
dc.source.identifierhttps://www.utupub.fi/handle/10024/165513
dc.titleInvestigating the short- and long-term effects of antibacterial agents using a real-time assay based on bioluminescent E. coli-lux
dc.year.issued2020

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S2405844020310768-main.pdf
Size:
2.72 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF