Arthroscopic Coracoclavicular Ligament Reconstruction Using Graft Augmentation and Titanium Implants

dc.contributor.authorJuha O. Ranne
dc.contributor.authorTerho U. Kainonen
dc.contributor.authorJussi A. Kosola
dc.contributor.authorLasse L. Lempainen
dc.contributor.authorKari J. Kanto
dc.contributor.authorJanne T. Lehtinen
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.converis.publication-id31225314
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/31225314
dc.date.accessioned2022-10-28T14:27:22Z
dc.date.available2022-10-28T14:27:22Z
dc.description.abstract<p>Several techniques have been introduced to treat acromioclavicular separation with coracoclavicular ligament reconstruction using graft augmentation. A modified <a title="Learn more about Arthroscopy" href="https://www.sciencedirect.com/topics/medicine-and-dentistry/arthroscopy"><u>arthroscopic</u></a> technique for coracoclavicular ligament reconstruction was used based on a previous technique where the supportive device and tendon graft share the clavicular and coracoid drill holes. A notable problem with the previous technique was large protruding <a title="Learn more about Suture Material" href="https://www.sciencedirect.com/topics/medicine-and-dentistry/suture-material"><u>suture</u></a> knots on the washer and clavicle, which could predispose to wound infection. In this modified technique, titanium implants were introduced. The implants hid the suture knot on the clavicle, and less foreign material was needed between the clavicular and coracoid implants.<br /></p>
dc.format.pagerangee465
dc.format.pagerangee471
dc.identifier.eissn2212-6287
dc.identifier.jour-issn2212-6287
dc.identifier.olddbid188370
dc.identifier.oldhandle10024/171464
dc.identifier.urihttps://www.utupub.fi/handle/11111/51663
dc.identifier.urnURN:NBN:fi-fe2021042719141
dc.language.isoen
dc.okm.affiliatedauthorRanne, Juha
dc.okm.affiliatedauthorLempainen, Lasse
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier B.V.
dc.publisher.countryNetherlandsen_GB
dc.publisher.countryAlankomaatfi_FI
dc.publisher.country-codeNL
dc.relation.doi10.1016/j.eats.2017.11.005
dc.relation.ispartofjournalArthroscopy Techniques
dc.relation.issue5
dc.relation.volume7
dc.source.identifierhttps://www.utupub.fi/handle/10024/171464
dc.titleArthroscopic Coracoclavicular Ligament Reconstruction Using Graft Augmentation and Titanium Implants
dc.year.issued2018

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S2212628717303845-main.pdf
Size:
1.99 MB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF