CLinical EValuation of WEB 17 device in intracranial aneuRysms (CLEVER): procedural, 30-day and 1-year safety results for ruptured and unruptured aneurysms

dc.contributor.authorSpelle Laurent
dc.contributor.authorCostalat Vincent
dc.contributor.authorCaroff Jildaz
dc.contributor.authorWodarg Fritz
dc.contributor.authorFischer Sebastian
dc.contributor.authorHerbreteau Denis
dc.contributor.authorMöhlenbruch Markus A.
dc.contributor.authorJanuel Anne-Christine
dc.contributor.authorPapagiannaki Chrysanthi
dc.contributor.authorKlisch Joachim
dc.contributor.authorNumminen Jussi
dc.contributor.authorRautio Riitta
dc.contributor.authorBerlis Ansgar
dc.contributor.authorMihalea Cristian
dc.contributor.authorChalumeau Vanessa
dc.contributor.authorDowner Jonathan
dc.contributor.authorCortese Jonathan
dc.contributor.authorIkka Léon
dc.contributor.authorGallas Sophie
dc.contributor.authorBester Maxim
dc.contributor.authorLiebig Thomas
dc.contributor.authorVelasco Stéphane
dc.contributor.authorGrimaldi Lamiae
dc.contributor.authorByrne James
dc.contributor.authorSzikora Istvan
dc.contributor.authorPierot Laurent
dc.contributor.authorCognard Christophe
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code2607303
dc.converis.publication-id380539285
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/380539285
dc.date.accessioned2025-08-28T00:31:22Z
dc.date.available2025-08-28T00:31:22Z
dc.description.abstract<p><b>Background</b> Intrasaccular flow disruption is an endovascular approach for the treatment of wide-neck aneurysms and, more specifically, wide-neck bifurcation aneurysms, which are challenging to treat with previously developed technologies. The Woven EndoBridge (WEB) device has demonstrated its efficacy and safety, for both unruptured and ruptured aneurysms.</p><p><b>Methods</b> The CLEVER study was an observational, multicenter, prospective study conducted in 17 European investigational sites using the WEB 17 device, for the treatment of ruptured and unruptured aneurysms. The study objective was to provide safety and efficacy data on the WEB 17 device in the treatment of wide-neck bifurcation aneurysms. Imaging results were assessed independently by a Corelab and adverse events adjudicated by a Clinical Event Adjudicator. This analysis reports procedural results and safety at 30 days and 12 months.</p><p><b>Results</b> A total of 163 patients (mean age 58.1 years; 68.1% women) with 103 unruptured aneurysms and 60 ruptured aneurysms were enrolled. Most aneurysms were located on the anterior communicating artery (ACom) (37.4%) or the middle cerebral artery (MCA) bifurcation (30.1%). Aneurysm widths ranged from 2.0–9.2 mm, and the mean sac width was 5.0 mm. The WEB procedure was successfully completed in 163 patients (100%). At the 12-month follow-up, major stroke events occurred in 3 of 163 patients (1.8%), and no device-related mortality was observed.</p><p><b>Conclusion</b> Endovascular treatment of ruptured and unruptured wide-neck bifurcation aneurysms using WEB 17 is safe, with a low complication rate and no device-related mortality. In particular, none of the ruptured aneurysms bled again up to 1 year of follow-up.</p><p><b>Trial registration number</b> NCT03844334.</p>
dc.identifier.eissn1759-8486
dc.identifier.jour-issn1759-8478
dc.identifier.olddbid205869
dc.identifier.oldhandle10024/188896
dc.identifier.urihttps://www.utupub.fi/handle/11111/35555
dc.identifier.urlhttps://jnis.bmj.com/content/early/2023/11/01/jnis-2023-020866
dc.identifier.urnURN:NBN:fi-fe2025082787146
dc.language.isoen
dc.okm.affiliatedauthorRautio, Riitta
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3112 Neurosciencesen_GB
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3112 Neurotieteetfi_FI
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherBMJ Publishing Group
dc.publisher.countryUnited Kingdomen_GB
dc.publisher.countryBritanniafi_FI
dc.publisher.country-codeGB
dc.relation.doi10.1136/jnis-2023-020866
dc.relation.ispartofjournalJournal of NeuroInterventional Surgery
dc.source.identifierhttps://www.utupub.fi/handle/10024/188896
dc.titleCLinical EValuation of WEB 17 device in intracranial aneuRysms (CLEVER): procedural, 30-day and 1-year safety results for ruptured and unruptured aneurysms
dc.year.issued2023

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
jnis-2023-020866.full.pdf
Size:
780.69 KB
Format:
Adobe Portable Document Format