Measurement of brown adipose tissue mass using a novel dual-echo magnetic resonance imaging approach: A validation study
| dc.contributor.author | Holstila M | |
| dc.contributor.author | Virtanen KA | |
| dc.contributor.author | Gronroos TJ | |
| dc.contributor.author | Laine J | |
| dc.contributor.author | Lepomaki V | |
| dc.contributor.author | Saunavaara J | |
| dc.contributor.author | Lisinen I | |
| dc.contributor.author | Komu M | |
| dc.contributor.author | Hannukainen LC | |
| dc.contributor.author | Nuutila P | |
| dc.contributor.author | Parkkola R | |
| dc.contributor.author | Borra RJH | |
| dc.contributor.organization | fi=PET-keskus|en=Turku PET Centre| | |
| dc.contributor.organization | fi=biolääketieteen laitos|en=Institute of Biomedicine| | |
| dc.contributor.organization | fi=kliininen laitos|en=Department of Clinical Medicine| | |
| dc.contributor.organization | fi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics| | |
| dc.contributor.organization | fi=lääketieteellinen tiedekunta|en=Faculty of Medicine| | |
| dc.contributor.organization | fi=sydäntutkimuskeskus|en=Cardiovascular Medicine (CAPC)| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.13290506867 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.14646305228 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.35734063924 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.61334543354 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.69079168212 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.77952289591 | |
| dc.converis.publication-id | 1533590 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/1533590 | |
| dc.date.accessioned | 2022-10-28T14:06:24Z | |
| dc.date.available | 2022-10-28T14:06:24Z | |
| dc.description.abstract | Objective<br />The aim of this study was to evaluate and validate magnetic resonance imaging (MRI) for the visualization and quantification of brown adipose tissue (BAT) in vivo in a rat model. We hypothesized that, based on differences in tissue water and lipid content, MRI could reliably differentiate between BAT and white adipose tissue (WAT) and could therefore be a possible alternative for 18 F-Fluorodeoxyglucose Positron Emission Tomography (18FDG-PET), the current gold standard for non-invasive BAT quantification.<br />Materials/Methods<br />Eleven rats were studied using both 18FDG-PET/CT and MRI (1.5 T). A dual echo (in-and-out-of-phase) sequence was used, both with and without spectral presaturation inversion recovery (SPIR) fat suppression (DUAL-SPIR) to visualize BAT, after which all BAT was surgically excised. The BAT volume measurements obtained via 18FDG-PET/CT and DUAL-SPIR MR were quantitatively compared with the histological findings. All study protocols were reviewed and approved by the local ethics committee.<br />Results<br />The BAT mass measurements that were obtained using DUAL-SPIR MR subtraction images correlated better with the histological findings (P = 0.017, R = 0.89) than did the measurements obtained using 18FDG-PET/CT (P = 0.78, R = 0.15), regardless of the BAT metabolic activation state. Additionally, the basic feasibility of the DUAL-SPIR method was demonstrated in three human pilot subjects.<br />Conclusions<br />This study demonstrates the potential for MRI to reliably detect and quantify BAT in vivo. MRI can provide information beyond that provided by 18FDG-PET imaging, and its ability to detect BAT is independent of its metabolic activation state. Additionally, MRI is a low-cost alternative that does not require radiation. | |
| dc.format.pagerange | 1189 | |
| dc.format.pagerange | 1198 | |
| dc.identifier.jour-issn | 0026-0495 | |
| dc.identifier.olddbid | 186294 | |
| dc.identifier.oldhandle | 10024/169388 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/36758 | |
| dc.identifier.urn | URN:NBN:fi-fe2021042714159 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Hannukainen, Jarna | |
| dc.okm.affiliatedauthor | Saunavaara, Jani | |
| dc.okm.affiliatedauthor | Parkkola, Riitta | |
| dc.okm.affiliatedauthor | Grönroos, Tove | |
| dc.okm.affiliatedauthor | Lisinen, Irina | |
| dc.okm.affiliatedauthor | Nuutila, Pirjo | |
| dc.okm.affiliatedauthor | Laine, Jukka | |
| dc.okm.affiliatedauthor | Borra, Ronald | |
| dc.okm.affiliatedauthor | Virtanen, Kirsi | |
| dc.okm.affiliatedauthor | Holstila, Milja | |
| dc.okm.discipline | 114 Physical sciences | en_GB |
| dc.okm.discipline | 3111 Biomedicine | en_GB |
| dc.okm.discipline | 3121 Internal medicine | en_GB |
| dc.okm.discipline | 114 Fysiikka | fi_FI |
| dc.okm.discipline | 3111 Biolääketieteet | fi_FI |
| dc.okm.discipline | 3121 Sisätaudit | fi_FI |
| dc.okm.internationalcopublication | not an international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | W B SAUNDERS CO-ELSEVIER INC | |
| dc.publisher.country | United States | en_GB |
| dc.publisher.country | Yhdysvallat (USA) | fi_FI |
| dc.publisher.country-code | US | |
| dc.relation.doi | 10.1016/j.metabol.2013.03.002 | |
| dc.relation.ispartofjournal | Metabolism | |
| dc.relation.issue | 8 | |
| dc.relation.volume | 62 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/169388 | |
| dc.title | Measurement of brown adipose tissue mass using a novel dual-echo magnetic resonance imaging approach: A validation study | |
| dc.year.issued | 2013 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Measurement.pdf
- Size:
- 586.78 KB
- Format:
- Adobe Portable Document Format
- Description:
- Final draft