Evaluation of Er:YAG and Er,Cr:YSGG lasers on intraradicular bonding using modified glass fiber tips
| dc.contributor.author | Sippus JH | |
| dc.contributor.author | Stape Thiago Henrique Scarabello | |
| dc.contributor.author | Tezvergil-Mutluay Arzu | |
| dc.contributor.organization | fi=hammaslääketieteen laitos|en=Institute of Dentistry| | |
| dc.contributor.organization | fi=tyks, vsshp|en=tyks, varha| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.64787032594 | |
| dc.converis.publication-id | 181983485 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/181983485 | |
| dc.date.accessioned | 2025-08-28T02:26:52Z | |
| dc.date.available | 2025-08-28T02:26:52Z | |
| dc.description.abstract | The aim of this study was to determine whether erbium laser irradiation emitted by modified glass-fiber tips would improve the intraradicular bonding of fiber posts. Forty human canines were endodontically treated and prepared for fiber-post placement. Roots were divided into five groups (n=8); according to the laser-tip combinations (2,940 nm Er:YAG and 2,780 nm Er,Cr:YSGG). Non-irradiated root canals served as control. Posts were cemented with self-adhesive resin cement and subjected to push-out test. Failure modes were characterized, and intraradicular bonded interfaces were analyzed by SEM and submitted to nanoleakage evaluation. Data were analyzed by two-way ANOVA and Tukey test (α=0.05). No significant differences were observed in cervical and middle sections (p>0.05), while significantly higher bond strengths were observed in apical sections (p<0.05). Laser irradiation reduced adhesive failures, cement-dentin gap formation, and nanoleakage apically. Laser-irradiation protocols employing end- or radial-firing tips improved bonding to apical intraradicular dentin contributing to more uniform bonded interfaces. | |
| dc.format.pagerange | 766 | |
| dc.format.pagerange | 773 | |
| dc.identifier.eissn | 1881-1361 | |
| dc.identifier.jour-issn | 0287-4547 | |
| dc.identifier.olddbid | 209105 | |
| dc.identifier.oldhandle | 10024/192132 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/39016 | |
| dc.identifier.urn | URN:NBN:fi-fe2025082788209 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Sippus, Jaana | |
| dc.okm.affiliatedauthor | Stape, Thiago | |
| dc.okm.affiliatedauthor | Tezvergil-Mutluay, Arzu | |
| dc.okm.affiliatedauthor | Dataimport, tyks, vsshp | |
| dc.okm.discipline | 217 Medical engineering | en_GB |
| dc.okm.discipline | 313 Dentistry | en_GB |
| dc.okm.discipline | 217 Lääketieteen tekniikka | fi_FI |
| dc.okm.discipline | 313 Hammaslääketieteet | fi_FI |
| dc.okm.internationalcopublication | not an international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher.country | Japan | en_GB |
| dc.publisher.country | Japani | fi_FI |
| dc.publisher.country-code | JP | |
| dc.relation.doi | 10.4012/dmj.2023-025 | |
| dc.relation.ispartofjournal | Dental Materials Journal | |
| dc.relation.issue | 6 | |
| dc.relation.volume | 42 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/192132 | |
| dc.title | Evaluation of Er:YAG and Er,Cr:YSGG lasers on intraradicular bonding using modified glass fiber tips | |
| dc.year.issued | 2023 |