Statistical Evaluation of Different Mathematical Models for Diffusion Weighted Imaging of Prostate Cancer Xenografts in Mice

dc.contributor.authorMerisaari Harri
dc.contributor.authorLaakso Hanne
dc.contributor.authorLiljenbäck Heidi
dc.contributor.authorVirtanen Helena
dc.contributor.authorAronen Hannu J.
dc.contributor.authorMinn Heikki
dc.contributor.authorPoutanen Matti
dc.contributor.authorRoivainen Anne
dc.contributor.authorLiimatainen Timo
dc.contributor.authorJambor Ivan
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=kliininen syöpätautioppi|en=Clinical Oncology|
dc.contributor.organizationfi=kuvantaminen ja kliininen diagnostiikka|en=Imaging and Clinical Diagnostics|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.69079168212
dc.contributor.organization-code1.2.246.10.2458963.20.74978886054
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.contributor.organization-code2607100
dc.converis.publication-id66417421
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/66417421
dc.date.accessioned2022-10-28T14:23:20Z
dc.date.available2022-10-28T14:23:20Z
dc.description.abstract<p><strong>Purpose </strong>To evaluate fitting quality and repeatability of four mathematical models for diffusion weighted imaging (DWI) during tumor progression in mouse xenograft model of prostate cancer.</p><p><strong>Methods</strong> Human prostate cancer cells (PC-3) were implanted subcutaneously in right hind limbs of 11 immunodeficient mice. Tumor growth was followed by weekly DWI examinations using a 7T MR scanner. Additional DWI examination was performed after repositioning following the fourth DWI examination to evaluate short term repeatability. DWI was performed using 15 and 12 b-values in the ranges of 0-500 and 0-2000 s/mm(2), respectively. Corrected Akaike information criteria and F-ratio were used to evaluate fitting quality of each model (mono-exponential, stretched exponential, kurtosis, and bi-exponential).</p><p><strong>Results</strong> Significant changes were observed in DWI data during the tumor growth, indicated by ADC(m), ADC(s), and ADC(k). Similar results were obtained using low as well as high b-values. No marked changes in model preference were present between the weeks 1-4. The parameters of the mono-exponential, stretched exponential, and kurtosis models had smaller confidence interval and coefficient of repeatability values than the parameters of the bi-exponential model.</p><p><strong>Conclusion</strong> Stretched exponential and kurtosis models showed better fit to DWI data than the mono-exponential model and presented with good repeatability.</p>
dc.identifier.eissn2234-943X
dc.identifier.jour-issn2234-943X
dc.identifier.olddbid187975
dc.identifier.oldhandle10024/171069
dc.identifier.urihttps://www.utupub.fi/handle/11111/43420
dc.identifier.urlhttps://www.frontiersin.org/articles/10.3389/fonc.2021.583921/full
dc.identifier.urnURN:NBN:fi-fe2021093049052
dc.language.isoen
dc.okm.affiliatedauthorMerisaari, Harri
dc.okm.affiliatedauthorLiljenbäck, Heidi
dc.okm.affiliatedauthorAronen, Hannu
dc.okm.affiliatedauthorVirtanen, Helena
dc.okm.affiliatedauthorMinn, Heikki
dc.okm.affiliatedauthorPoutanen, Matti
dc.okm.affiliatedauthorJambor, Ivan
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.affiliatedauthorRoivainen, Anne
dc.okm.discipline3122 Cancersen_GB
dc.okm.discipline3122 Syöpätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherFRONTIERS MEDIA SA
dc.publisher.countrySwitzerlanden_GB
dc.publisher.countrySveitsifi_FI
dc.publisher.country-codeCH
dc.relation.articlenumberARTN 583921
dc.relation.doi10.3389/fonc.2021.583921
dc.relation.ispartofjournalFrontiers in Oncology
dc.relation.volume11
dc.source.identifierhttps://www.utupub.fi/handle/10024/171069
dc.titleStatistical Evaluation of Different Mathematical Models for Diffusion Weighted Imaging of Prostate Cancer Xenografts in Mice
dc.year.issued2021

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
MerisaariEtAl2021StatisticalEvaluation.pdf
Size:
2 MB
Format:
Adobe Portable Document Format
Description:
Publisher's pdf