Does postoperative orbital volume predict postoperative globe malposition after blow-out fracture reconstruction? A 6-month clinical follow-up study

dc.contributor.authorSnäll J.
dc.contributor.authorNarjus-Sterba M.
dc.contributor.authorToivari M.
dc.contributor.authorWilkman T.
dc.contributor.authorThorén H.
dc.contributor.organizationfi=hammaslääketieteen laitos|en=Institute of Dentistry|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.64787032594
dc.converis.publication-id39776605
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/39776605
dc.date.accessioned2022-10-28T14:20:44Z
dc.date.available2022-10-28T14:20:44Z
dc.description.abstract<div>Purpose: The aim of this study was to investigate the relationship between intraorbital volume change caused by orbital fracture and globe malposition (GMP) in blow-out fracture patients undergoing surgery and to clarify the significance of different radiologically detected predictors associated with GMP.</div><div><br /></div><div>Patients and methods: A 6-month prospective follow-up study of unilateral isolated orbital fractures was designed and implemented. The main outcome variable was GMP (present or absent); the secondary outcome was orientation of GMP (horizontal or vertical). The primary predictor variable was postoperative orbital volume difference determined as the difference between the fractured and non-fractured orbit (measured in milliliter and analyzed in milliliter and percentages). The explanatory variables were gender, age, treatment delay from trauma to surgery, fracture site, horizontal depth of the fracture, fracture area, maximum vertical dislocation of the fracture, and preoperative volume difference.</div><div><br /></div><div>Results: A total of 15 patients fulfilled the inclusion criteria and were followed for 6months from a larger cohort. GMP was detected in 6/15 patients (40.0%). GMP was more often present in large (2.5cm(2)) fractures (55.6%), in combined orbital fractures (50.0%), and in fractures with preoperative volume difference 2.5ml (62.5%) regardless of the postoperative volume correction. Postoperatively, patients with and without GMP displayed overcorrection of orbital volume; 4.15% corresponded to 1.15ml (with GMP) and 7.6% corresponded to 1.9ml (without GMP).</div><div><br /></div><div>Conclusion: GMP was present in large and combined orbital fractures. Clinically detectable postoperative GMP occurred despite satisfactory orbital reconstruction and overcorrection. Mild GMP, however, is not significant for the patient.</div>
dc.format.pagerange27
dc.format.pagerange34
dc.identifier.jour-issn1865-1550
dc.identifier.olddbid187716
dc.identifier.oldhandle10024/170810
dc.identifier.urihttps://www.utupub.fi/handle/11111/43236
dc.identifier.urlhttps://link.springer.com/article/10.1007/s10006-019-00748-3
dc.identifier.urnURN:NBN:fi-fe2021042826162
dc.language.isoen
dc.okm.affiliatedauthorThoren, Hanna
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3126 Surgery, anesthesiology, intensive care, radiologyen_GB
dc.okm.discipline3126 Kirurgia, anestesiologia, tehohoito, radiologiafi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSPRINGER HEIDELBERG
dc.publisher.countryGermanyen_GB
dc.publisher.countrySaksafi_FI
dc.publisher.country-codeDE
dc.relation.doi10.1007/s10006-019-00748-3
dc.relation.ispartofjournalOral and Maxillofacial Surgery
dc.relation.issue1
dc.relation.volume23
dc.source.identifierhttps://www.utupub.fi/handle/10024/170810
dc.titleDoes postoperative orbital volume predict postoperative globe malposition after blow-out fracture reconstruction? A 6-month clinical follow-up study
dc.year.issued2019

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Snäll2019_Article_DoesPostoperativeOrbitalVolume.pdf
Size:
528.25 KB
Format:
Adobe Portable Document Format
Description:
Publisher's PDF