Correlation between 18F-Sodium Fluoride positron emission tomography and bone histomorphometry in dialysis patients

dc.contributor.authorLouise Aaltonen
dc.contributor.authorNiina Koivuviita
dc.contributor.authorMarko Seppänen
dc.contributor.authorXiaoyu Tong
dc.contributor.authorHeikki Kröger
dc.contributor.authorEliisa Löyttyniemi
dc.contributor.authorKaj Metsärinne
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=biostatistiikka|en=Biostatistics|
dc.contributor.organizationfi=kliininen laitos|en=Department of Clinical Medicine|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.61334543354
dc.contributor.organization-code1.2.246.10.2458963.20.89365200099
dc.converis.publication-id46737136
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/46737136
dc.date.accessioned2022-10-28T12:33:11Z
dc.date.available2022-10-28T12:33:11Z
dc.description.abstract<p><b>B</b>ackground</p><div><p>The diagnosis of renal osteodystrophy is challenging. Bone biopsy is the gold standard, but it is invasive and limited to one site of the skeleton. The ability of biomarkers to estimate the underlying bone pathology is limited. 18F-Sodium Fluoride positron emission tomography (18F-NaF PET) is a noninvasive quantitative imaging technique that allows assessment of regional bone turnover at clinically relevant sites. The hypothesis of this study was, that 18F-NaF PET correlates with bone histomorphometry in dialysis patients and could act as a noninvasive diagnostic tool in this patient group.</p></div><div><h3>Methods</h3><p>This was a cross-sectional diagnostic test study. 26 dialysis patients with biochemical abnormalities indicating mineral and bone disorder were included. All the participants underwent a 18F-NaF PET scan and a bone biopsy. Fluoride activity in the PET scan was measured in the lumbar spine and at the anterior iliac crest. Dynamic and static histomorphometric parameters of the bone biopsy were assessed. As histomorphometric markers for bone turnover we used bone formation rate per bone surface (BFR/BS) and activation frequency per year (Ac.f).</p></div><div><h3>Results</h3><p>There was a statistically significant correlation between fluoride activity in the 18F-NaF PET scan and histomorphometric parameters such as bone formation rate, activation frequency and osteoclast and osteoblast surfaces and mineralized surfaces. 18F-NaF PET's sensitivity to recognize low turnover in respect to non-low turnover was 76% and specificity 78%. Because of the small number of patients with high turnover, we were unable to demonstrate significant predictive value in this group.</p></div><div><h3>Conclusions</h3><p>A clear correlation between histomorphometric parameters and fluoride activity in the 18F-NaF PET scan was established. 18F-NaF PET may possibly be a noninvasive diagnostic tool in dialysis patients with low turnover bone disease, but further research is needed.</p></div>
dc.identifier.eissn1873-2763
dc.identifier.jour-issn8756-3282
dc.identifier.olddbid177251
dc.identifier.oldhandle10024/160345
dc.identifier.urihttps://www.utupub.fi/handle/11111/33280
dc.identifier.urnURN:NBN:fi-fe2021042825137
dc.language.isoen
dc.okm.affiliatedauthorAaltonen, Louise
dc.okm.affiliatedauthorKoivuviita, Niina
dc.okm.affiliatedauthorSeppänen, Marko
dc.okm.affiliatedauthorLöyttyniemi, Eliisa
dc.okm.affiliatedauthorMetsärinne, Kaj
dc.okm.affiliatedauthorDataimport, 2609820 PET Tutkimus
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3121 Internal medicineen_GB
dc.okm.discipline3121 Sisätauditfi_FI
dc.okm.internationalcopublicationnot an international co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherElsevier Inc.
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1016/j.bone.2020.115267
dc.relation.ispartofjournalBONE
dc.relation.volume134
dc.source.identifierhttps://www.utupub.fi/handle/10024/160345
dc.titleCorrelation between 18F-Sodium Fluoride positron emission tomography and bone histomorphometry in dialysis patients
dc.year.issued2020

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
1-s2.0-S8756328220300478-main (1).pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
Description:
Publisher's version