Assessment of a digital and an analog PET/CT system for accurate myocardial perfusion imaging with a flow phantom
| dc.contributor.author | Siekkinen Reetta | |
| dc.contributor.author | Kirjavainen Anna K | |
| dc.contributor.author | Koskensalo Kalle | |
| dc.contributor.author | Smith Nadia AS | |
| dc.contributor.author | Fenwick Andrew | |
| dc.contributor.author | Saunavaara Virva | |
| dc.contributor.author | Tolvanen Tuula | |
| dc.contributor.author | Iida Hidehiro | |
| dc.contributor.author | Saraste Antti | |
| dc.contributor.author | Teräs Mika | |
| dc.contributor.author | Teuho Jarmo | |
| dc.contributor.organization | fi=PET-keskus|en=Turku PET Centre| | |
| dc.contributor.organization | fi=biolääketieteen laitos|en=Institute of Biomedicine| | |
| dc.contributor.organization | fi=kliininen fysiologia ja isotooppilääketiede|en=Clinical Physiology and Isotope Medicine| | |
| dc.contributor.organization | fi=sisätautioppi|en=Internal Medicine| | |
| dc.contributor.organization | fi=tyks, vsshp|en=tyks, varha| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.14646305228 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.40502528769 | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.77952289591 | |
| dc.contributor.organization-code | 2607322 | |
| dc.contributor.organization-code | 2609810 | |
| dc.converis.publication-id | 58940170 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/58940170 | |
| dc.date.accessioned | 2022-10-28T13:50:41Z | |
| dc.date.available | 2022-10-28T13:50:41Z | |
| dc.description.abstract | In Myocardial Perfusion Imaging (MPI) with Positron Emission Tomography/Computed Tomography (PET/CT) systems, accurate quantification is essential. We assessed flow quantification accuracy over various injected activities using a flow phantom.Methods The study was performed on the digital 4-ring Discovery MI (DMI-20) and analog Discovery 690 (D690) PET/CT systems, using 325-1257 MBq of [O-15]H2O. PET performance and flow quantification accuracy were assessed in terms of count-rates, dead-time factors (DTF), scatter fractions (SF), time-activity curves (TACs), areas-under-the-curves (AUCs) and flow values.Results On DMI-20, prompts of 12.8 Mcps, DTF of 2.06 and SF of 46.1% were measured with 1257 MBq of activity. On the D690, prompts of 6.85 Mcps, DTF of 1.57 and SF of 32.5% were measured with 1230 MBq of activity. AUC values were linear over all activities. Mean wash-in flow error was - 9% for both systems whereas wash-out flow error was - 5% and - 6% for DMI-20 and D690. With the highest activity, wash-out flow error was - 12% and - 7% for the DMI-20 and D690.Conclusion DMI-20 and D690 preserved accurate flow quantification over all injected activities, with maximum error of - 12%. In the future, flow quantification accuracy over the activities and count-rates evaluated in this study should be assessed. | |
| dc.format.pagerange | 1964 | |
| dc.format.pagerange | 1972 | |
| dc.identifier.eissn | 1532-6551 | |
| dc.identifier.jour-issn | 1071-3581 | |
| dc.identifier.olddbid | 184692 | |
| dc.identifier.oldhandle | 10024/167786 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/51243 | |
| dc.identifier.url | https://link.springer.com/article/10.1007/s12350-021-02631-9 | |
| dc.identifier.urn | URN:NBN:fi-fe2021093048802 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Dataimport, 2609820 PET Tutkimus | |
| dc.okm.affiliatedauthor | Siekkinen, Reetta | |
| dc.okm.affiliatedauthor | Kirjavainen, Anna | |
| dc.okm.affiliatedauthor | Koskensalo, Kalle | |
| dc.okm.affiliatedauthor | Saunavaara, Virva | |
| dc.okm.affiliatedauthor | Iida, Hidehiro | |
| dc.okm.affiliatedauthor | Tolvanen, Tuula | |
| dc.okm.affiliatedauthor | Saraste, Antti | |
| dc.okm.affiliatedauthor | Teräs, Mika | |
| dc.okm.affiliatedauthor | Teuho, Jarmo | |
| dc.okm.affiliatedauthor | Dataimport, tyks, vsshp | |
| dc.okm.discipline | 3111 Biomedicine | en_GB |
| dc.okm.discipline | 3111 Biolääketieteet | fi_FI |
| dc.okm.internationalcopublication | international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | Springer | |
| dc.publisher.country | United States | en_GB |
| dc.publisher.country | Yhdysvallat (USA) | fi_FI |
| dc.publisher.country-code | US | |
| dc.relation.doi | 10.1007/s12350-021-02631-9 | |
| dc.relation.ispartofjournal | Journal of Nuclear Cardiology | |
| dc.relation.volume | 29 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/167786 | |
| dc.title | Assessment of a digital and an analog PET/CT system for accurate myocardial perfusion imaging with a flow phantom | |
| dc.year.issued | 2022 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- Siekkinen2021_Article_AssessmentOfADigitalAndAnAnalo.pdf
- Size:
- 701.28 KB
- Format:
- Adobe Portable Document Format
- Description:
- Publisher's pdf