Assessment of a digital and an analog PET/CT system for accurate myocardial perfusion imaging with a flow phantom

dc.contributor.authorSiekkinen Reetta
dc.contributor.authorKirjavainen Anna K
dc.contributor.authorKoskensalo Kalle
dc.contributor.authorSmith Nadia AS
dc.contributor.authorFenwick Andrew
dc.contributor.authorSaunavaara Virva
dc.contributor.authorTolvanen Tuula
dc.contributor.authorIida Hidehiro
dc.contributor.authorSaraste Antti
dc.contributor.authorTeräs Mika
dc.contributor.authorTeuho Jarmo
dc.contributor.organizationfi=PET-keskus|en=Turku PET Centre|
dc.contributor.organizationfi=biolääketieteen laitos|en=Institute of Biomedicine|
dc.contributor.organizationfi=kliininen fysiologia ja isotooppilääketiede|en=Clinical Physiology and Isotope Medicine|
dc.contributor.organizationfi=sisätautioppi|en=Internal Medicine|
dc.contributor.organizationfi=tyks, vsshp|en=tyks, varha|
dc.contributor.organization-code1.2.246.10.2458963.20.14646305228
dc.contributor.organization-code1.2.246.10.2458963.20.40502528769
dc.contributor.organization-code1.2.246.10.2458963.20.77952289591
dc.contributor.organization-code2607322
dc.contributor.organization-code2609810
dc.converis.publication-id58940170
dc.converis.urlhttps://research.utu.fi/converis/portal/Publication/58940170
dc.date.accessioned2022-10-28T13:50:41Z
dc.date.available2022-10-28T13:50:41Z
dc.description.abstractIn Myocardial Perfusion Imaging (MPI) with Positron Emission Tomography/Computed Tomography (PET/CT) systems, accurate quantification is essential. We assessed flow quantification accuracy over various injected activities using a flow phantom.Methods The study was performed on the digital 4-ring Discovery MI (DMI-20) and analog Discovery 690 (D690) PET/CT systems, using 325-1257 MBq of [O-15]H2O. PET performance and flow quantification accuracy were assessed in terms of count-rates, dead-time factors (DTF), scatter fractions (SF), time-activity curves (TACs), areas-under-the-curves (AUCs) and flow values.Results On DMI-20, prompts of 12.8 Mcps, DTF of 2.06 and SF of 46.1% were measured with 1257 MBq of activity. On the D690, prompts of 6.85 Mcps, DTF of 1.57 and SF of 32.5% were measured with 1230 MBq of activity. AUC values were linear over all activities. Mean wash-in flow error was - 9% for both systems whereas wash-out flow error was - 5% and - 6% for DMI-20 and D690. With the highest activity, wash-out flow error was - 12% and - 7% for the DMI-20 and D690.Conclusion DMI-20 and D690 preserved accurate flow quantification over all injected activities, with maximum error of - 12%. In the future, flow quantification accuracy over the activities and count-rates evaluated in this study should be assessed.
dc.format.pagerange1964
dc.format.pagerange1972
dc.identifier.eissn1532-6551
dc.identifier.jour-issn1071-3581
dc.identifier.olddbid184692
dc.identifier.oldhandle10024/167786
dc.identifier.urihttps://www.utupub.fi/handle/11111/51243
dc.identifier.urlhttps://link.springer.com/article/10.1007/s12350-021-02631-9
dc.identifier.urnURN:NBN:fi-fe2021093048802
dc.language.isoen
dc.okm.affiliatedauthorDataimport, 2609820 PET Tutkimus
dc.okm.affiliatedauthorSiekkinen, Reetta
dc.okm.affiliatedauthorKirjavainen, Anna
dc.okm.affiliatedauthorKoskensalo, Kalle
dc.okm.affiliatedauthorSaunavaara, Virva
dc.okm.affiliatedauthorIida, Hidehiro
dc.okm.affiliatedauthorTolvanen, Tuula
dc.okm.affiliatedauthorSaraste, Antti
dc.okm.affiliatedauthorTeräs, Mika
dc.okm.affiliatedauthorTeuho, Jarmo
dc.okm.affiliatedauthorDataimport, tyks, vsshp
dc.okm.discipline3111 Biomedicineen_GB
dc.okm.discipline3111 Biolääketieteetfi_FI
dc.okm.internationalcopublicationinternational co-publication
dc.okm.internationalityInternational publication
dc.okm.typeA1 ScientificArticle
dc.publisherSpringer
dc.publisher.countryUnited Statesen_GB
dc.publisher.countryYhdysvallat (USA)fi_FI
dc.publisher.country-codeUS
dc.relation.doi10.1007/s12350-021-02631-9
dc.relation.ispartofjournalJournal of Nuclear Cardiology
dc.relation.volume29
dc.source.identifierhttps://www.utupub.fi/handle/10024/167786
dc.titleAssessment of a digital and an analog PET/CT system for accurate myocardial perfusion imaging with a flow phantom
dc.year.issued2022

Tiedostot

Näytetään 1 - 1 / 1
Ladataan...
Name:
Siekkinen2021_Article_AssessmentOfADigitalAndAnAnalo.pdf
Size:
701.28 KB
Format:
Adobe Portable Document Format
Description:
Publisher's pdf