Noncompetitive Chromogenic Lateral-Flow Immunoassay for Simultaneous Detection of Microcystins and Nodularin
| dc.contributor.author | Sultana Akter | |
| dc.contributor.author | Teemu Kustila | |
| dc.contributor.author | Janne Leivo | |
| dc.contributor.author | Gangatharan Muralitharan | |
| dc.contributor.author | Markus Vehniäinen | |
| dc.contributor.author | Urpo Lamminmäki | |
| dc.contributor.organization | fi=biotekniikka|en=Biotechnology| | |
| dc.contributor.organization-code | 1.2.246.10.2458963.20.98373201676 | |
| dc.contributor.organization-code | 2606202 | |
| dc.contributor.organization-code | 2606203 | |
| dc.converis.publication-id | 40724475 | |
| dc.converis.url | https://research.utu.fi/converis/portal/Publication/40724475 | |
| dc.date.accessioned | 2022-10-28T14:08:05Z | |
| dc.date.available | 2022-10-28T14:08:05Z | |
| dc.description.abstract | <h2>Abstract</h2><b>:</b> <div>Cyanobacterial blooms cause local and global health issues by contaminating surface waters. Microcystins and nodularins are cyclic cyanobacterial peptide toxins comprising numerous natural variants. Most of them are potent hepatotoxins, tumor promoters, and at least microcystin-LR is possibly carcinogenic. In drinking water, the World Health Organization (WHO) recommended the provisional guideline value of 1 µg/L for microcystin-LR. For water used for recreational activity, the guidance values for microcystin concentration varies mostly between 4–25 µg/L in different countries. Current immunoassays or lateral flow strips for microcystin/nodularin are based on indirect competitive method, which are generally more prone to sample interference and sometimes hard to interpret compared to two-site immunoassays. Simple, sensitive, and easy to interpret user-friendly methods for first line screening of microcystin/nodularin near water sources are needed for assessment of water quality and safety. We describe the development of a two-site sandwich format lateral-flow assay for the rapid detection of microcystins and nodularin-R. A unique antibody fragment capable of broadly recognizing immunocomplexes consisting of a capture antibody bound to microcystins/nodularin-R was used to develop the simple lateral flow immunoassay. The assay can visually detect the major hepatotoxins (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF -LW, and nodularin-R) at and below the concentration of 4 µg/L. The signal is directly proportional to the concentration of the respective toxin, and the use of alkaline phosphatase activity offers a cost efficient alternative by eliminating the need of toxin conjugates or other labeling system. The easy to interpret assay has the potential to serve as a microcystins/nodularin screening tool for those involved in water quality monitoring such as municipal authorities, researchers, as well as general public concerned of bathing water quality.</div> <div><div>Keywords:</div> noncompetitive immunoassay; cyanotoxin; microcystin; nodularin; lateral flow</div> | |
| dc.identifier.eissn | 2079-6374 | |
| dc.identifier.jour-issn | 2079-6374 | |
| dc.identifier.olddbid | 186466 | |
| dc.identifier.oldhandle | 10024/169560 | |
| dc.identifier.uri | https://www.utupub.fi/handle/11111/38570 | |
| dc.identifier.url | https://www.mdpi.com/2079-6374/9/2/79/html | |
| dc.identifier.urn | URN:NBN:fi-fe2021042825242 | |
| dc.language.iso | en | |
| dc.okm.affiliatedauthor | Akter, Sultana | |
| dc.okm.affiliatedauthor | Kustila, Teemu | |
| dc.okm.affiliatedauthor | Leivo, Janne | |
| dc.okm.affiliatedauthor | Vehniäinen, Markus | |
| dc.okm.affiliatedauthor | Lamminmäki, Urpo | |
| dc.okm.discipline | 1172 Environmental sciences | en_GB |
| dc.okm.discipline | 1182 Biochemistry, cell and molecular biology | en_GB |
| dc.okm.discipline | 1183 Plant biology, microbiology, virology | en_GB |
| dc.okm.discipline | 219 Environmental biotechnology | en_GB |
| dc.okm.discipline | 3142 Public health care science, environmental and occupational health | en_GB |
| dc.okm.discipline | 1172 Ympäristötiede | fi_FI |
| dc.okm.discipline | 1182 Biokemia, solu- ja molekyylibiologia | fi_FI |
| dc.okm.discipline | 1183 Kasvibiologia, mikrobiologia, virologia | fi_FI |
| dc.okm.discipline | 219 Ympäristön bioteknologia | fi_FI |
| dc.okm.discipline | 3142 Kansanterveystiede, ympäristö ja työterveys | fi_FI |
| dc.okm.internationalcopublication | international co-publication | |
| dc.okm.internationality | International publication | |
| dc.okm.type | A1 ScientificArticle | |
| dc.publisher | MDPI AG, Basel, Switzerland | |
| dc.publisher.place | Basel | |
| dc.relation.articlenumber | 79 | |
| dc.relation.doi | 10.3390/bios9020079 | |
| dc.relation.ispartofjournal | Biosensors | |
| dc.relation.issue | 2 | |
| dc.relation.volume | 9 | |
| dc.source.identifier | https://www.utupub.fi/handle/10024/169560 | |
| dc.title | Noncompetitive Chromogenic Lateral-Flow Immunoassay for Simultaneous Detection of Microcystins and Nodularin | |
| dc.year.issued | 2019 |
Tiedostot
1 - 1 / 1
Ladataan...
- Name:
- biosensors-09-00079-v2.pdf
- Size:
- 2.3 MB
- Format:
- Adobe Portable Document Format
- Description:
- Publisher's PDF